{"id":5537,"date":"2026-11-23T02:35:28","date_gmt":"2026-11-23T02:35:28","guid":{"rendered":"https:\/\/hetapro.com\/?page_id=5537"},"modified":"2026-11-23T02:46:38","modified_gmt":"2026-11-23T02:46:38","slug":"chemical-pharma-heat-pump-solutions","status":"publish","type":"page","link":"https:\/\/hetapro.com\/es\/chemical-pharma-heat-pump-solutions\/","title":{"rendered":""},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"5537\" class=\"elementor elementor-5537\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66fdd14 e-flex e-con-boxed e-con e-parent\" data-id=\"66fdd14\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-402a84f elementor-widget elementor-widget-html\" data-id=\"402a84f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<!DOCTYPE html>\r\n<html lang=\"en\">\r\n<head>\r\n<meta charset=\"UTF-8\">\r\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1\">\r\n<title>Heat Pumps for Chemical &amp; Pharma | HETAPRO<\/title>\r\n<meta name=\"description\" content=\"Industrial heat pumps for chemical processing and pharmaceutical manufacturing - distillation, evaporation, drying, CIP and clean utilities, 30-150\u00b0C, with a 10-year TCO calculator.\">\r\n<link rel=\"canonical\" href=\"https:\/\/hetapro.com\/chemical-pharma-heat-pump-solutions\/\">\r\n<meta name=\"robots\" content=\"index,follow,max-image-preview:large\">\r\n<meta property=\"og:type\" content=\"website\">\r\n<meta property=\"og:locale\" content=\"en_US\">\r\n<meta property=\"og:site_name\" content=\"HETAPRO\">\r\n<meta property=\"og:title\" content=\"Heat Pumps for Chemical &amp; Pharma | HETAPRO\">\r\n<meta property=\"og:description\" content=\"Reboilers, dryers, reactor jackets and clean utilities: 30\u00b0C to 150\u00b0C process heat, with the GMP and ATEX boundaries stated before you ask.\">\r\n<meta property=\"og:url\" content=\"https:\/\/hetapro.com\/chemical-pharma-heat-pump-solutions\/\">\r\n<meta property=\"og:image\" content=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/11\/hero-bg-chemical-and-pharma.webp\">\r\n<meta property=\"og:image:type\" content=\"image\/webp\">\r\n<meta property=\"og:image:alt\" content=\"Aerial view of a chemical process plant with distillation columns, pipe racks and utility units\">\r\n<meta name=\"theme-color\" content=\"#170A0C\">\r\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\r\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\r\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Inter:wght@400..700&display=swap\" rel=\"stylesheet\">\r\n<link rel=\"preload\" as=\"image\" href=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/11\/hero-bg-chemical-and-pharma.webp\" type=\"image\/webp\" media=\"(min-width: 641px)\">\r\n<style>\r\n\r\n:root{\r\n  --ink:#170A0C; --ink2:#2A1114; --body:#4A3A3C; --muted:#7A6669;\r\n  --line:#E8E0E1; --bg:#ffffff; --soft:#FAF7F7; --soft2:#F2EBEC;\r\n  --accent:#E60012; --accent-dk:#B8000E; --accent-soft:#FDEAEC;\r\n  --graphite:#4A3236; --graphite-soft:#F5EEEF;\r\n  --warn:#B45309; --warn-soft:#FDF3E7;\r\n  --red:#9B111E; --red-soft:#FBE9EA;\r\n  --green:#15803D; --green-soft:#EAF7EE;\r\n  --radius:10px; --maxw:1160px;\r\n}\r\n*{box-sizing:border-box}\r\nhtml{scroll-behavior:smooth}\r\nbody{\r\n  margin:0; background:var(--bg); color:var(--body);\r\n  font-family:Inter,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,sans-serif;\r\n  font-size:16.5px; line-height:1.72; -webkit-font-smoothing:antialiased;\r\n}\r\n.wrap{max-width:var(--maxw); margin:0 auto; padding:0 24px}\r\nh1,h2,h3,h4{color:var(--ink); line-height:1.22; letter-spacing:-.015em; margin:0 0 .5em}\r\nh1{font-size:clamp(1.95rem,4.4vw,3.15rem); font-weight:700}\r\nh2{font-size:clamp(1.45rem,2.9vw,2.05rem); font-weight:700; margin-top:2.4em}\r\nh3{font-size:clamp(1.13rem,2vw,1.32rem); font-weight:650; margin-top:1.9em}\r\nh4{font-size:1.03rem; font-weight:650; margin-top:1.4em}\r\np{margin:0 0 1.05em}\r\na{color:var(--accent-dk)}\r\nstrong{color:var(--ink); font-weight:650}\r\n.eyebrow{font-size:.76rem; letter-spacing:.14em; text-transform:uppercase; color:var(--accent); font-weight:600; margin-bottom:10px}\r\n\r\n.nav{position:sticky; top:0; z-index:50; background:rgba(255,255,255,.93); backdrop-filter:blur(10px); border-bottom:1px solid var(--line)}\r\n.nav .wrap{display:flex; align-items:center; justify-content:space-between; height:62px}\r\n.brand{font-weight:700; color:var(--ink); letter-spacing:.02em; font-size:1.05rem; text-decoration:none}\r\n.brand span{color:var(--accent)}\r\n.nav-links{display:flex; gap:22px; align-items:center; font-size:.87rem}\r\n.nav-links a{color:var(--muted); text-decoration:none}\r\n.nav-links a:hover{color:var(--ink)}\r\n.btn{display:inline-block; padding:11px 20px; border-radius:8px; font-weight:600; font-size:.9rem; text-decoration:none; border:1px solid transparent; cursor:pointer; transition:.16s}\r\n.btn-p{background:var(--accent); color:#fff}\r\n.btn-p:hover{background:var(--accent-dk)}\r\n.btn-o{border-color:var(--line); color:var(--ink); background:#fff}\r\n.btn-o:hover{border-color:var(--accent); color:var(--accent-dk)}\r\n\r\n\/* ---------- HERO ---------- *\/\r\n.hero{position:relative; color:#FDF6F6; padding:66px 0 54px; isolation:isolate; background:var(--ink); overflow:hidden}\r\n\/* \u9996\u5c4f\u80cc\u666f\uff1a\u6e29\u5ba4\u5168\u666f\uff0c\u73bb\u7483\u9876 + \u6696\u8272\u82b1\u7530\uff0c\u9700\u5f3a\u65b9\u5411\u6027\u906e\u7f69\u4fdd\u8bc1\u767d\u5b57\u53ef\u8bfb *\/\r\n.hero-bg{position:absolute; inset:0; z-index:-2; overflow:hidden}\r\n.hero-bg img{width:100%; height:100%; object-fit:cover; object-position:center 45%; display:block;\r\n  filter:saturate(.94) contrast(1.05)}\r\n\/* \u906e\u7f69\u4e09\u5c42\uff1a\u5de6\u4fa7\u6587\u5b57\u533a\u538b\u5230 96%\uff0c\u53f3\u4fa7\u7559 32% \u8ba9\u6e29\u5ba4\u82b1\u7530\u6210\u4e3a\u4e3b\u4f53\uff1b\u6696\u68d5\u9ed1\u800c\u975e\u7eaf\u7ea2\uff0c\u907f\u514d\u4e0e\u9ec4\u82b1\u649e\u8272 *\/\r\n.hero-veil{position:absolute; inset:0; z-index:-1;\r\n  background:\r\n    radial-gradient(120% 90% at 78% 42%, rgba(230,0,18,.10) 0%, rgba(230,0,18,.03) 40%, rgba(230,0,18,0) 65%),\r\n    linear-gradient(100deg,\r\n      rgba(12,10,12,.97) 0%,\r\n      rgba(14,11,13,.95) 24%,\r\n      rgba(16,12,14,.88) 40%,\r\n      rgba(18,13,15,.72) 54%,\r\n      rgba(20,14,16,.50) 68%,\r\n      rgba(22,15,17,.34) 82%,\r\n      rgba(24,16,18,.42) 100%),\r\n    linear-gradient(180deg,\r\n      rgba(12,10,12,.58) 0%,\r\n      rgba(12,10,12,.22) 28%,\r\n      rgba(12,10,12,.10) 50%,\r\n      rgba(12,10,12,.55) 80%,\r\n      rgba(12,10,12,.86) 100%)}\r\n.hero h1{color:#fff; text-shadow:0 2px 30px rgba(16,7,9,.8), 0 1px 5px rgba(16,7,9,.6)}\r\n.hero .eyebrow{color:#FFB0B7; font-size:.76rem; letter-spacing:.14em; text-transform:uppercase; font-weight:600; margin-bottom:14px; text-shadow:0 1px 14px rgba(16,7,9,.9)}\r\n.hero .lede{font-size:1.1rem; max-width:790px; color:#F4E7E8; text-shadow:0 2px 18px rgba(16,7,9,.85), 0 1px 3px rgba(16,7,9,.55)}\r\n\/* \u6781\u7a84\u5c4f\u9690\u53bb\u80cc\u666f\u56fe\uff0c\u907f\u514d\u62a2 LCP *\/\r\n@media (max-width:640px){\r\n  .hero-bg{display:none}\r\n}\r\n.hero strong,.hero b{color:#FFFFFF}\r\n.specbar{display:grid; grid-template-columns:repeat(4,1fr); gap:1px; margin-top:34px; background:rgba(255,255,255,.18); border:1px solid rgba(255,255,255,.18); border-radius:var(--radius); overflow:hidden}\r\n.specbar div{background:rgba(20,9,11,.78); padding:16px 18px}\r\n.specbar b{display:block; font-size:1.16rem; color:#fff; font-weight:650; letter-spacing:-.01em}\r\n.specbar span{font-size:.77rem; color:#E0CCCE; text-transform:uppercase; letter-spacing:.06em}\r\n\r\n\/* ---------- NOTES \/ CARDS ---------- *\/\r\n.note{border-left:3px solid var(--accent); background:var(--accent-soft); padding:16px 20px; border-radius:0 var(--radius) var(--radius) 0; margin:22px 0; font-size:.96rem}\r\n.note.warn{border-color:var(--warn); background:var(--warn-soft)}\r\n.note.deep{border-color:var(--graphite); background:var(--graphite-soft)}\r\n.note b.lbl{display:block; font-size:.76rem; letter-spacing:.08em; text-transform:uppercase; color:var(--accent-dk); margin-bottom:5px}\r\n.note.warn b.lbl{color:var(--warn)}\r\n.note.deep b.lbl{color:var(--graphite)}\r\n\r\n.cards{display:grid; gap:16px; margin:22px 0}\r\n.c3{grid-template-columns:repeat(3,1fr)}\r\n.c4{grid-template-columns:repeat(4,1fr)}\r\n.c2{grid-template-columns:repeat(2,1fr)}\r\n.card{border:1px solid var(--line); border-radius:var(--radius); padding:20px 22px; background:#fff}\r\n.card h4{margin-top:0}\r\n.card p{font-size:.92rem; margin-bottom:0}\r\n.card .num{color:var(--accent); font-size:.8rem; font-weight:600; letter-spacing:.05em; display:block; margin-bottom:6px}\r\n\r\n\/* ---------- TABLES ---------- *\/\r\n.tbl-wrap{overflow-x:auto; margin:24px 0; border:1px solid var(--line); border-radius:var(--radius)}\r\ntable{width:100%; border-collapse:collapse; font-size:.9rem; min-width:680px}\r\ncaption{caption-side:top; text-align:left; font-size:.82rem; color:var(--muted); padding:14px 16px 10px; font-style:italic; background:var(--soft); border-bottom:1px solid var(--line)}\r\nth,td{padding:11px 14px; text-align:left; border-bottom:1px solid var(--line); vertical-align:top}\r\nth{background:var(--soft2); color:var(--ink); font-weight:650; font-size:.8rem; text-transform:uppercase; letter-spacing:.04em}\r\ntbody tr:last-child td{border-bottom:none}\r\ntbody tr:nth-child(even){background:#FDFBFB}\r\ntd.num{font-variant-numeric:tabular-nums; font-size:.86rem; white-space:nowrap}\r\n.pill{display:inline-block; padding:2px 9px; border-radius:20px; font-size:.7rem; font-weight:650; letter-spacing:.03em; white-space:nowrap}\r\n.p-hi{background:var(--green-soft); color:var(--green)}\r\n.p-mid{background:var(--warn-soft); color:var(--warn)}\r\n.p-lo{background:var(--red-soft); color:var(--red)}\r\n.p-ind{background:var(--soft2); color:var(--graphite)}\r\n\r\na.plink{color:inherit; text-decoration:none; border-bottom:1px dashed rgba(230,0,18,.45); transition:.15s}\r\na.plink:hover{border-bottom-style:solid; color:var(--accent-dk)}\r\n\r\n\/* ---------- PROCESS FINDER ---------- *\/\r\n.finder{border:1px solid var(--line); border-radius:14px; background:#fff; margin:30px 0; overflow:hidden; box-shadow:0 1px 3px rgba(23,10,12,.05)}\r\n.finder-head{padding:24px 30px 20px; background:linear-gradient(160deg,#170A0C,#331114); color:#FDF6F6}\r\n.finder-head .kicker{font-size:.72rem; letter-spacing:.14em; text-transform:uppercase; color:#FF9AA3; font-weight:600}\r\n.finder-head h2{color:#fff; margin:8px 0; font-size:clamp(1.3rem,2.4vw,1.7rem)}\r\n.finder-head p{color:#E0CBCD; margin:0; font-size:.94rem; max-width:720px}\r\n.chips{display:flex; flex-wrap:wrap; gap:8px; padding:20px 30px 6px}\r\n.chip{border:1px solid var(--line); background:#fff; color:var(--graphite); border-radius:999px; padding:7px 15px; font-size:.83rem; font-weight:600; cursor:pointer; transition:.15s; font-family:inherit}\r\n.chip:hover{border-color:var(--accent); color:var(--accent-dk)}\r\n.chip[aria-pressed=\"true\"]{background:var(--accent); border-color:var(--accent); color:#fff}\r\n.pf-grid{display:grid; grid-template-columns:repeat(2,1fr); gap:12px; padding:16px 30px 30px}\r\n.pfind-item{border:1px solid var(--line); border-radius:var(--radius); padding:14px 16px; background:#fff}\r\n.pfind-item[hidden]{display:none}\r\n.pf-top{display:flex; align-items:baseline; justify-content:space-between; gap:10px; margin-bottom:3px}\r\n.pf-top b{font-size:.96rem; color:var(--ink); letter-spacing:-.01em}\r\n.pf-row{font-size:.82rem; color:var(--muted); display:flex; gap:6px; flex-wrap:wrap}\r\n.pf-row .k{color:var(--graphite); font-weight:600}\r\n.pf-row .v{color:var(--body)}\r\n.pf-temp{font-variant-numeric:tabular-nums; font-weight:650; color:var(--accent-dk); white-space:nowrap; font-size:.85rem}\r\n.pf-sum{padding:0 30px 22px; font-size:.84rem; color:var(--muted)}\r\n\r\n\/* ---------- SERIES SELECTOR ---------- *\/\r\n.tshell{border:1px solid var(--line); border-radius:14px; background:#fff; margin:30px 0; overflow:hidden; box-shadow:0 1px 3px rgba(23,10,12,.05)}\r\n.tshell-head{padding:26px 30px 20px; background:linear-gradient(160deg,#170A0C,#331114); color:#FDF6F6}\r\n.tshell-head .kicker{font-size:.73rem; letter-spacing:.14em; text-transform:uppercase; color:#FF9AA3; font-weight:600}\r\n.tshell-head h2{color:#fff; margin:8px 0; font-size:clamp(1.3rem,2.4vw,1.72rem)}\r\n.tshell-head p{color:#E0CBCD; margin:0; max-width:790px; font-size:.95rem}\r\n.tshell-head strong,.tshell-head b{color:#fff}\r\n.tstage{padding:26px 30px 6px}\r\n.tslider-wrap{position:relative; padding:6px 0 0}\r\n.tslider{-webkit-appearance:none; appearance:none; width:100%; height:8px; border-radius:99px; outline:none; margin:14px 0 0; cursor:pointer;\r\n  background:linear-gradient(90deg,#3B6EA5 0%,#7FB8A8 28%,#D4A04A 62%,#E60012 100%)}\r\n.tslider::-webkit-slider-thumb{-webkit-appearance:none; width:30px; height:30px; border-radius:50%; background:#fff; border:4px solid var(--ink); box-shadow:0 2px 8px rgba(23,10,12,.30); cursor:grab}\r\n.tslider::-webkit-slider-thumb:active{cursor:grabbing}\r\n.tslider::-moz-range-thumb{width:26px; height:26px; border-radius:50%; background:#fff; border:4px solid var(--ink); box-shadow:0 2px 8px rgba(23,10,12,.30); cursor:grab}\r\n.tslider:focus-visible{box-shadow:0 0 0 4px rgba(230,0,18,.25)}\r\n.ticks{position:relative; height:1.2em; margin:12px 15px 0; font-size:.74rem; color:var(--muted); font-variant-numeric:tabular-nums}\r\n.ticks span{position:absolute; top:0; transform:translateX(-50%); white-space:nowrap}\r\n.ticks span:first-child{transform:translateX(-4px)}\r\n.ticks span:last-child{transform:translateX(-100%)}\r\n.ticks b{color:var(--ink); font-weight:600}\r\n\r\n.treadout{display:grid; grid-template-columns:210px 1fr; gap:0; border:1px solid var(--line); border-radius:var(--radius); overflow:hidden; margin:24px 0 8px; background:#fff}\r\n.tbig{background:var(--ink); color:#fff; padding:24px 22px; display:flex; flex-direction:column; justify-content:center; align-items:flex-start}\r\n.tbig .lab{font-size:.68rem; letter-spacing:.12em; text-transform:uppercase; color:#C1A6A9; margin-bottom:6px}\r\n.tbig .val{font-size:2.5rem; font-weight:700; line-height:1; font-variant-numeric:tabular-nums; letter-spacing:-.02em}\r\n.tbig .val small{font-size:1.1rem; font-weight:500; color:#CDB4B7}\r\n.tbig .tseriesname{margin-top:9px; font-size:.82rem; color:#FF9AA3; font-weight:600; font-variant-numeric:tabular-nums}\r\n.tbody{padding:20px 24px}\r\n.tbody h4{margin:0 0 8px; font-size:1.06rem}\r\n.tbody p{margin:0 0 12px; font-size:.94rem}\r\n.tspecs{display:grid; grid-template-columns:repeat(auto-fit,minmax(130px,1fr)); gap:12px; margin-top:14px}\r\n.tspec{background:var(--soft); border:1px solid var(--line); border-radius:8px; padding:10px 12px}\r\n.tspec b{display:block; font-size:.96rem; color:var(--ink); font-variant-numeric:tabular-nums; font-weight:500}\r\n.tspec span{font-size:.71rem; text-transform:uppercase; letter-spacing:.05em; color:var(--muted)}\r\n\r\n.tcards{display:grid; grid-template-columns:repeat(3,1fr); gap:12px; margin:24px 0 0; padding:24px 30px 30px; background:var(--soft); border-top:1px solid var(--line)}\r\n.tcards-h{grid-column:1\/-1; font-size:.78rem; letter-spacing:.11em; text-transform:uppercase; color:var(--muted); font-weight:600; margin-bottom:-2px}\r\n.series{position:relative; background:#fff; border:1px solid var(--line); border-radius:var(--radius); padding:14px 15px; transition:.2s; overflow:hidden; display:flex; flex-direction:column; cursor:pointer}\r\n.series::before{content:\"\"; position:absolute; left:0; top:0; bottom:0; width:3px; background:var(--line); transition:.2s}\r\n.series .sn{font-variant-numeric:tabular-nums; font-size:.74rem; color:var(--muted); font-weight:500}\r\n.series .st{font-size:.95rem; font-weight:700; color:var(--ink); margin:2px 0 4px; font-variant-numeric:tabular-nums; letter-spacing:-.015em; white-space:nowrap}\r\n.series .sl{font-size:.86rem; font-weight:650; color:var(--accent-dk); margin-bottom:6px; line-height:1.32}\r\n.series p{font-size:.79rem; margin:0; color:var(--body); line-height:1.55; flex:1}\r\n.series.active{border-color:var(--accent); box-shadow:0 4px 16px rgba(230,0,18,.14); transform:translateY(-2px)}\r\n.series.active::before{background:var(--accent)}\r\n.series.active .sn{color:var(--accent)}\r\n\r\n\/* ---------- TCO CALCULATOR ---------- *\/\r\n.calc{border:1px solid var(--line); border-radius:14px; background:#fff; margin:34px 0; overflow:hidden}\r\n.calc-head{padding:24px 30px 20px; border-bottom:1px solid var(--line); background:var(--soft)}\r\n.calc-head .kicker{font-size:.73rem; letter-spacing:.13em; text-transform:uppercase; color:var(--accent); font-weight:600}\r\n.calc-head h3{margin:7px 0 5px; font-size:clamp(1.2rem,2.2vw,1.42rem)}\r\n.calc-head p{margin:0; font-size:.92rem; color:var(--muted); max-width:820px}\r\n.calc-body{display:grid; grid-template-columns:1fr 1fr; gap:0}\r\n.calc-in{padding:24px 30px; border-right:1px solid var(--line)}\r\n.calc-out{padding:24px 30px; background:var(--soft)}\r\n.fld{margin-bottom:19px}\r\n.fld:last-child{margin-bottom:0}\r\n.fld label{display:flex; justify-content:space-between; align-items:baseline; gap:10px; font-size:.87rem; font-weight:600; color:var(--ink); margin-bottom:9px}\r\n.fld label b{font-variant-numeric:tabular-nums; color:var(--accent-dk); font-size:.95rem; font-weight:600; white-space:nowrap}\r\n.fld .hint{font-size:.78rem; color:var(--muted); font-weight:400; margin-top:7px; line-height:1.5}\r\n.calc-in input[type=range]{-webkit-appearance:none; appearance:none; width:100%; height:5px; border-radius:99px; background:var(--soft2); outline:none; cursor:pointer}\r\n.calc-in input[type=range]::-webkit-slider-thumb{-webkit-appearance:none; width:20px; height:20px; border-radius:50%; background:#fff; border:3px solid var(--accent); box-shadow:0 1px 5px rgba(23,10,12,.22); cursor:grab}\r\n.calc-in input[type=range]::-moz-range-thumb{width:16px; height:16px; border-radius:50%; background:#fff; border:3px solid var(--accent); box-shadow:0 1px 5px rgba(23,10,12,.22); cursor:grab}\r\n.calc-in input[type=range]:focus-visible{box-shadow:0 0 0 4px rgba(230,0,18,.18)}\r\n.res{display:flex; justify-content:space-between; align-items:baseline; gap:12px; padding:11px 0; border-bottom:1px dashed var(--line)}\r\n.res:last-of-type{border-bottom:none}\r\n.res .k{font-size:.86rem; color:var(--body)}\r\n.res .v{font-variant-numeric:tabular-nums; font-size:1rem; color:var(--ink); font-weight:500; text-align:right; white-space:nowrap}\r\n.res.hero{background:#fff; border:1px solid var(--line); border-radius:8px; padding:14px 16px; margin-bottom:10px; display:block}\r\n.res.hero .k{font-size:.79rem; text-transform:uppercase; letter-spacing:.06em; color:var(--muted); display:block; margin-bottom:4px}\r\n.res.hero .v{font-size:1.85rem; font-weight:700; color:var(--ink); display:block; text-align:left; letter-spacing:-.02em}\r\n.res.hero .v.up{color:var(--green)} .res.hero .v.dn{color:var(--red)}\r\n.bars{margin:16px 0 6px; padding-top:4px; border-top:1px solid var(--line)}\r\n.bar-row{margin-bottom:10px}\r\n.bar-lab{display:flex; justify-content:space-between; gap:10px; font-size:.78rem; color:var(--body); margin-bottom:4px}\r\n.bar-lab b{font-variant-numeric:tabular-nums; color:var(--ink); font-weight:600}\r\n.bar-track{height:13px; border-radius:4px; background:var(--soft2); overflow:hidden}\r\n.bar-fill{height:100%; border-radius:4px; transition:width .35s ease}\r\n.bar-fill.b-boiler{background:#9A8386}\r\n.bar-fill.b-hp{background:var(--accent)}\r\n.verdict{margin-top:14px; padding:13px 15px; border-radius:8px; font-size:.86rem; line-height:1.6; border:1px solid transparent}\r\n.verdict.ok{background:var(--green-soft); color:#14532D; border-color:#BBF7D0}\r\n.verdict.mid{background:var(--warn-soft); color:#7A3A0E; border-color:#FDE68A}\r\n.verdict.no{background:var(--red-soft); color:#7F1017; border-color:#FECACA}\r\n.verdict b{color:inherit}\r\n.calc-foot{font-size:.76rem; color:var(--muted); margin:12px 0 0; line-height:1.55}\r\n.pcard.rec{border-color:var(--accent); box-shadow:0 4px 16px rgba(230,0,18,.12)}\r\n.pcard.rec::before{content:\"\"; position:absolute; left:0; right:0; top:0; height:3px; background:var(--accent); z-index:2}\r\n\r\n\/* ---------- FIGURES ---------- *\/\r\nfigure{margin:28px 0}\r\n.figbox{border:1px solid var(--line); border-radius:var(--radius); background:#fff; overflow:hidden}\r\n.figbox svg{display:block; width:100%; height:auto}\r\nfigcaption{font-size:.83rem; color:var(--muted); line-height:1.6; padding:12px 16px; background:var(--soft); border-top:1px solid var(--line)}\r\nfigcaption b{color:var(--ink)}\r\n.fg-box{fill:#FAF7F7; stroke:#E8E0E1; stroke-width:1}\r\n.fg-box-a{fill:#FDEAEC; stroke:#E60012; stroke-width:1.4}\r\n.fg-box-d{fill:#170A0C; stroke:#170A0C}\r\n.fg-t{fill:#170A0C; font:600 13px Inter,\"Segoe UI\",sans-serif}\r\n.fg-tb{fill:#170A0C; font:700 14px Inter,\"Segoe UI\",sans-serif}\r\n.fg-tw{fill:#FFFFFF; font:700 13px Inter,\"Segoe UI\",sans-serif}\r\n.fg-s{fill:#7A6669; font:400 11px Inter,\"Segoe UI\",sans-serif}\r\n.fg-sw{fill:#D9BFC2; font:400 11px Inter,\"Segoe UI\",sans-serif}\r\n.fg-m{fill:#4A3A3C; font:500 12px Inter,\"Segoe UI\",sans-serif}\r\n.fg-a{fill:#B8000E; font:700 12px Inter,\"Segoe UI\",sans-serif}\r\n.fg-al{fill:#E60012; font:700 11px Inter,\"Segoe UI\",sans-serif}\r\n.fg-line{stroke:#E8E0E1; stroke-width:1}\r\n.fg-arrow{stroke:#4A3236; stroke-width:1.5; fill:none; marker-end:url(#fa)}\r\n.fg-arrow-a{stroke:#E60012; stroke-width:1.75; fill:none; marker-end:url(#faa)}\r\n.fg-dash{stroke:#B45309; stroke-width:1.25; stroke-dasharray:5 4; fill:none; marker-end:url(#fa)}\r\n\r\n\/* ---------- FORMULA ---------- *\/\r\n.formula{background:var(--ink); color:#F0DFE0; padding:18px 22px; border-radius:var(--radius); font-variant-numeric:tabular-nums; font-size:.88rem; margin:20px 0; overflow-x:auto; line-height:1.9}\r\n.formula b{color:#FF9AA3}\r\n\r\n\/* ---------- PRODUCT CARDS ---------- *\/\r\n.pshell{border:1px solid var(--line); border-radius:14px; background:#fff; margin:34px 0; overflow:hidden; box-shadow:0 1px 3px rgba(23,10,12,.05)}\r\n.pshell-head{padding:26px 30px 20px; background:linear-gradient(160deg,#170A0C,#331114); color:#FDF6F6}\r\n.pshell-head .kicker{font-size:.73rem; letter-spacing:.14em; text-transform:uppercase; color:#FF9AA3; font-weight:600}\r\n.pshell-head h2{color:#fff; margin:8px 0; font-size:clamp(1.3rem,2.4vw,1.72rem)}\r\n.pshell-head p{color:#E0CBCD; margin:0; max-width:780px; font-size:.95rem}\r\n.pshell-head strong,.pshell-head b{color:#fff}\r\n.pshell-body{padding:26px 30px 30px}\r\n.pgrid{display:grid; grid-template-columns:repeat(3,1fr); gap:16px}\r\n.pcard{border:1px solid var(--line); border-radius:var(--radius); background:#fff; overflow:hidden; transition:.2s; position:relative; display:flex; flex-direction:column}\r\n.pcard:hover{border-color:var(--accent); box-shadow:0 4px 16px rgba(230,0,18,.11)}\r\n.pcard-top{padding:14px 18px 12px; border-bottom:1px solid var(--line); background:var(--soft)}\r\n.pcard-top .pmodel{font-size:1.08rem; font-weight:650; color:var(--ink); letter-spacing:-.01em}\r\n.pcard-top .ptag{font-size:.7rem; letter-spacing:.05em; text-transform:uppercase; color:var(--muted); margin-top:2px}\r\n.pimg{position:relative; background:#fff; border-bottom:1px solid var(--line); aspect-ratio:4\/2.9; overflow:hidden; display:flex; align-items:center; justify-content:center}\r\n.pimg img{width:100%; height:100%; object-fit:contain; padding:12px; display:block; transition:transform .35s ease}\r\n.pcard:hover .pimg img{transform:scale(1.04)}\r\n.pimg::after{content:\"\"; position:absolute; inset:0; pointer-events:none; background:radial-gradient(ellipse at 50% 45%,rgba(255,255,255,0) 55%,rgba(240,235,233,.5) 100%)}\r\n.pcard-body{padding:14px 18px 18px; flex:1; display:flex; flex-direction:column}\r\n.pcard-body p{font-size:.87rem; margin:0 0 12px; color:var(--body)}\r\n.pspecs{display:grid; grid-template-columns:repeat(2,1fr); gap:1px; background:var(--line); border:1px solid var(--line); border-radius:8px; overflow:hidden; margin-bottom:12px}\r\n.pspec{background:#fff; padding:8px 11px}\r\n.pspec b{display:block; font-size:.85rem; color:var(--ink); font-variant-numeric:tabular-nums; font-weight:500; line-height:1.3}\r\n.pspec span{font-size:.65rem; text-transform:uppercase; letter-spacing:.05em; color:var(--muted)}\r\n.pcard a.pmore{margin-top:auto; font-size:.83rem; font-weight:600; color:var(--accent-dk); text-decoration:none}\r\n.pcard a.pmore:hover{text-decoration:underline}\r\n\r\n\/* ---------- STEPS ---------- *\/\r\n.steps{counter-reset:s; margin:22px 0; padding:0; list-style:none}\r\n.steps li{counter-increment:s; position:relative; padding:0 0 20px 50px}\r\n.steps li::before{content:counter(s); position:absolute; left:0; top:0; width:30px; height:30px; border-radius:50%; background:var(--accent-soft); color:var(--accent-dk); font-weight:700; font-size:.86rem; display:flex; align-items:center; justify-content:center}\r\n.steps li::after{content:\"\"; position:absolute; left:15px; top:32px; bottom:2px; width:1px; background:var(--line)}\r\n.steps li:last-child::after{display:none}\r\n.steps h4{margin:3px 0 4px}\r\n.steps p{font-size:.91rem; margin:0}\r\n\r\n\/* ---------- FAQ ---------- *\/\r\n.faq details{border:1px solid var(--line); border-radius:var(--radius); margin-bottom:10px; background:#fff; overflow:hidden}\r\n.faq summary{cursor:pointer; padding:15px 20px; font-weight:600; color:var(--ink); list-style:none; display:flex; justify-content:space-between; gap:14px; align-items:flex-start}\r\n.faq summary::-webkit-details-marker{display:none}\r\n.faq summary::after{content:\"+\"; font-size:1.3rem; color:var(--muted); line-height:1; flex-shrink:0}\r\n.faq details[open] summary::after{content:\"\u2212\"}\r\n.faq .ans{padding:0 20px 17px; font-size:.95rem}\r\n\r\n\/* ---------- CTA \/ FOOTER ---------- *\/\r\n.cta{background:linear-gradient(150deg,#170A0C,#331114); color:#F7EBEC; border-radius:var(--radius); padding:38px 34px; margin:44px 0}\r\n.cta h2{color:#fff; margin-top:0}\r\n.cta p{color:#D8BFC2}\r\n.cta strong,.cta b{color:#FFFFFF}\r\n.btn-outline{background:transparent; color:var(--accent); border-color:var(--accent); padding:10px 18px; font-weight:600; text-shadow:0 1px 2px rgba(10,4,5,.75)}\r\n.btn-outline:hover{background:var(--accent); color:#fff; border-color:var(--accent); text-shadow:none}\r\nfooter{border-top:1px solid var(--line); margin-top:56px; padding:30px 0 44px; font-size:.84rem; color:var(--muted)}\r\n.src{font-size:.82rem; color:var(--muted)}\r\n.src li{margin-bottom:7px}\r\n\r\n@media (max-width:1000px){\r\n  .pgrid{grid-template-columns:repeat(2,1fr)}\r\n  .c4{grid-template-columns:repeat(2,1fr)}\r\n}\r\n@media (max-width:900px){\r\n  .pf-grid{grid-template-columns:1fr}\r\n  .c3,.c2{grid-template-columns:1fr}\r\n  .specbar{grid-template-columns:repeat(2,1fr)}\r\n  .nav-links .hide-sm{display:none}\r\n  .finder-head,.chips,.pf-grid,.pf-sum,.pshell-head,.pshell-body{padding-left:20px; padding-right:20px}\r\n}\r\n@media (max-width:560px){\r\n  .pgrid{grid-template-columns:1fr}\r\n}\r\n@media (max-width:900px){\r\n  .treadout{grid-template-columns:1fr}\r\n  .tcards{grid-template-columns:repeat(2,1fr)}\r\n  .tshell-head,.tstage,.tcards,.calc-head,.calc-in,.calc-out{padding-left:20px; padding-right:20px}\r\n  .calc-body{grid-template-columns:1fr}\r\n  .calc-in{border-right:none; border-bottom:1px solid var(--line)}\r\n}\r\n@media (max-width:560px){\r\n  .tcards{grid-template-columns:1fr}\r\n  .tbig .val{font-size:2.1rem}\r\n  .ticks span:nth-child(even){display:none}\r\n  .ticks span:first-child, .ticks span:last-child{display:block}\r\n}\r\n\r\n\/* ---------- \u9996\u5c4f\u4e0b\u65b9\u7ae0\u8282 tab \u6761\uff08\u65e0 logo\uff09 ---------- *\/\r\n.tabbar{position:sticky; top:var(--site-header-h,72px); z-index:60; background:rgba(255,255,255,.96); backdrop-filter:blur(10px); border-bottom:1px solid var(--line); box-shadow:0 3px 14px rgba(11,43,66,.07)}\r\n.tabbar .wrap{display:flex; align-items:center; min-height:58px}\r\n.tabs{display:flex; align-items:stretch; gap:2px; flex:1 1 auto; min-width:0; overflow-x:auto; scrollbar-width:none; -ms-overflow-style:none}\r\n.tabs::-webkit-scrollbar{display:none}\r\n.tab{position:relative; flex:0 0 auto; display:inline-flex; align-items:center; gap:8px; padding:17px 15px; font-size:.86rem; font-weight:600; color:var(--muted); text-decoration:none; white-space:nowrap; border-bottom:2px solid transparent; transition:color .16s,background .16s,border-color .16s}\r\n.tab:hover{color:var(--ink); background:var(--accent-soft)}\r\n.tab .tab-n{font-family:ui-monospace,SFMono-Regular,Consolas,monospace; font-size:.68rem; letter-spacing:.03em; color:#b6bdc5}\r\n.tab[aria-current=\"location\"]{color:var(--accent-dk); border-bottom-color:var(--accent)}\r\n.tab[aria-current=\"location\"] .tab-n{color:var(--accent)}\r\n.tab-cta{margin-left:14px; flex:0 0 auto; align-self:center; padding:9px 16px; border:1px solid var(--accent); border-radius:7px; background:var(--accent); color:#fff; font-size:.82rem; font-weight:700; border-bottom:1px solid var(--accent); text-decoration:none}\r\n.tab-cta:hover{background:var(--accent-dk); border-color:var(--accent-dk); color:#fff}\r\n#series,#finder,#plant,#clean-steam,#products,#tco{scroll-margin-top:calc(var(--site-header-h,72px) + 76px)}\r\n@media (max-width:760px){\r\n  .tabbar .wrap{padding:0 12px}\r\n  .tab{padding:15px 12px; font-size:.8rem; gap:6px}\r\n  .tab-cta{margin-left:8px; padding:8px 12px; font-size:.76rem}\r\n}\r\n\r\n<\/style>\r\n<script type=\"application\/ld+json\">\r\n{\r\n  \"@context\": \"https:\/\/schema.org\",\r\n  \"@graph\": [\r\n    {\r\n      \"@type\": \"WebPage\",\r\n      \"@id\": \"https:\/\/hetapro.com\/chemical-pharma-heat-pump-solutions\/\",\r\n      \"url\": \"https:\/\/hetapro.com\/chemical-pharma-heat-pump-solutions\/\",\r\n      \"name\": \"Heat Pumps for Chemical & Pharma\",\r\n      \"description\": \"Industrial high-temperature heat pumps for chemical processing and pharmaceutical manufacturing: distillation, evaporation, drying, solvent recovery, CIP and clean utilities, 30-150\u00b0C.\",\r\n      \"isPartOf\": {\"@type\": \"WebSite\", \"name\": \"HETAPRO\", \"url\": \"https:\/\/hetapro.com\/\"},\r\n      \"provider\": {\"@type\": \"Organization\", \"name\": \"HETAPRO\", \"url\": \"https:\/\/hetapro.com\/\"}\r\n    },\r\n    {\r\n      \"@type\": \"Service\",\r\n      \"name\": \"Chemical & pharmaceutical heat pump solutions\",\r\n      \"serviceType\": \"Industrial heat pump sizing and supply for chemical plants and pharmaceutical sites\",\r\n      \"provider\": {\"@type\": \"Organization\", \"name\": \"HETAPRO\"},\r\n      \"areaServed\": \"Worldwide\",\r\n      \"description\": \"Six heat pump series from 30\u00b0C to 150\u00b0C for distillation reboilers, evaporators, drying, reactor jackets, solvent recovery, CIP and clean utility preheat.\"\r\n    },\r\n    {\r\n      \"@type\": \"BreadcrumbList\",\r\n      \"itemListElement\": [\r\n        {\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/hetapro.com\/\"},\r\n        {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Chemical & Pharma\", \"item\": \"https:\/\/hetapro.com\/chemical-pharma-heat-pump-solutions\/\"}\r\n      ]\r\n    },\r\n    {\r\n      \"@type\": \"FAQPage\",\r\n      \"mainEntity\": [\r\n        {\r\n          \"@type\": \"Question\",\r\n          \"name\": \"Can a heat pump make process steam for a chemical plant?\",\r\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, up to about 150\u00b0C and roughly 5 bar with current commercial cascade machines. Published chemical installations include a 50 MW thermal unit at BASF Ludwigshafen supplying steam for formic acid production, and an AstraZeneca site in Sweden with a 500 kW heat pump delivering steam at 10 bar. Above 150\u00b0C the sector is still pre-commercial: the honest answer there is a hybrid, with the heat pump carrying the base load and a fired heater supplying the peak.\"}\r\n        },\r\n        {\r\n          \"@type\": \"Question\",\r\n          \"name\": \"What about the 121\u00b0C autoclave and GMP clean steam?\",\r\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A sterilising autoclave at 121\u00b0C for 20 minutes or 134\u00b0C for 5 minutes is a validated pressure vessel with defined steam quality, air removal and IQ\/OQ\/PQ records. It should stay on its validated clean-steam generator. The heat pump works upstream: preheating boiler feedwater, carrying the utility hot-water loop and feeding the clean-steam generator's primary side through a double tube-sheet exchanger. Refrigerant never enters the clean side.\"}\r\n        },\r\n        {\r\n          \"@type\": \"Question\",\r\n          \"name\": \"Where does the waste heat come from on a batch plant?\",\r\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Distillation and vacuum condensers at 35\u201360\u00b0C, reactor cooling water at 40\u201390\u00b0C, hot condensate and effluent at 50\u201395\u00b0C, and chiller condensers at 30\u201340\u00b0C. Batch timing is the difficulty, not the temperature: a buffer tank lets a 90-minute exotherm feed a machine that runs all day. Size the buffer before you size the heat pump.\"}\r\n        },\r\n        {\r\n          \"@type\": \"Question\",\r\n          \"name\": \"Is it safe in a solvent or ATEX area?\",\r\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It can be, but the zone classification comes first. Specify Ex-rated electrical components, a low-charge natural refrigerant where practical, and an indirect water or glycol loop that keeps the machine outside Zone 1. Materials of construction and refrigerant choice are then reviewed against the solvent and the process pressure boundary.\"}\r\n        },\r\n        {\r\n          \"@type\": \"Question\",\r\n          \"name\": \"How does a heat pump compare with mechanical vapour recompression?\",\r\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"They are usually complementary rather than rivals. MVR compresses the vapour boiled off in one evaporation effect; a heat pump lifts heat from a separate low-grade source to a higher-temperature sink. In a typical study the heat pump preheats the feed, MVR handles the evaporation effect, and a boiler keeps a small trim duty. Ask for both options priced in the same report.\"}\r\n        },\r\n        {\r\n          \"@type\": \"Question\",\r\n          \"name\": \"What COP should I assume for a distillation reboiler?\",\r\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It depends on the condenser and reboiler temperatures, not on the machine's nameplate. Lifting heat from a 40\u201360\u00b0C condenser to a 95\u2013130\u00b0C reboiler typically lands at 2.5\u20133.4. Vacuum columns with a 35\u201355\u00b0C condenser and an 80\u201395\u00b0C reboiler can reach 3.4\u20133.9. Use the selector on this page for a first pass, then replace the figure with a guaranteed value at your own duty point.\"}\r\n        }\r\n      ]\r\n    }\r\n  ]\r\n}\r\n<\/script>\r\n<\/head>\r\n<body>\r\n\r\n\r\n\r\n<header class=\"hero\">\r\n  <div class=\"hero-bg\"><img src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/11\/hero-bg-chemical-and-pharma.webp\"\r\n       srcset=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/11\/hero-bg-chemical-and-pharma-768x432.webp 768w,\r\n               https:\/\/hetapro.com\/wp-content\/uploads\/2026\/11\/hero-bg-chemical-and-pharma-1024x576.webp 1024w,\r\n               https:\/\/hetapro.com\/wp-content\/uploads\/2026\/11\/hero-bg-chemical-and-pharma.webp 1600w\"\r\n       sizes=\"100vw\" width=\"1600\" height=\"900\" fetchpriority=\"high\" decoding=\"async\"\r\n       alt=\"Aerial view of a chemical process plant with distillation columns, pipe racks and utility units\"><\/div>\r\n  <div class=\"hero-veil\" aria-hidden=\"true\"><\/div>\r\n  <div class=\"wrap\">\r\n    <div class=\"eyebrow\">Applications \u00b7 Chemical &amp; Pharmaceutical \u00b7 2026<\/div>\r\n    <h1>Distil it.<br>Dry it.<br>Keep it sterile.<\/h1>\r\n    <p class=\"lede\">A chemical site moves more heat than almost anything else. A column boils at the bottom and rejects heat at the top; a reactor exotherm runs alongside a jacket that needs 120 \u00b0C; a tablet dryer throws away warm, moist air. Most of that heat leaves at 30\u201390 \u00b0C while the process wants 80\u2013150 \u00b0C. A HETAPRO heat pump closes the gap \u2014 and states the boundary honestly: above roughly 150 \u00b0C, and inside a validated autoclave, steam still has a job.<\/p>\r\n    <div class=\"specbar\">\r\n      <div><b>30\u2013150 \u00b0C<\/b><span>Hot water \u00b7 steam \u00b7 hot air<\/span><\/div>\r\n      <div><b>6 series<\/b><span>Matched to each unit operation<\/span><\/div>\r\n      <div><b>2.0\u20135.2 COP<\/b><span>Falls as the temperature lift rises<\/span><\/div>\r\n      <div><b>24\/7 duty<\/b><span>Continuous plants carry the capital<\/span><\/div>\r\n    <\/div>\r\n  <\/div>\r\n<\/header>\r\n\r\n<nav class=\"tabbar\" aria-label=\"Page section navigation\">\r\n  <div class=\"wrap\">\r\n    <div class=\"tabs\">\r\n      <a class=\"tab\" href=\"#series\"><span class=\"tab-n\">01<\/span>Series selector<\/a>\r\n      <a class=\"tab\" href=\"#finder\"><span class=\"tab-n\">02<\/span>Process index<\/a>\r\n      <a class=\"tab\" href=\"#plant\"><span class=\"tab-n\">03<\/span>On the plant<\/a>\r\n      <a class=\"tab\" href=\"#clean-steam\"><span class=\"tab-n\">04<\/span>Clean steam<\/a>\r\n      <a class=\"tab\" href=\"#products\"><span class=\"tab-n\">05<\/span>Products<\/a>\r\n      <a class=\"tab\" href=\"#tco\"><span class=\"tab-n\">06<\/span>Cost calculator<\/a>\r\n    <\/div>\r\n    <a class=\"tab tab-cta\" href=\"https:\/\/hetapro.com\/contact\/\">Contact us<\/a>\r\n  <\/div>\r\n<\/nav>\r\n\r\n<main class=\"wrap\">\r\n\r\n<!-- ============ SERIES SELECTOR ============ -->\r\n<section class=\"tshell\" id=\"series\">\r\n  <div class=\"tshell-head\">\r\n    <div class=\"kicker\">Interactive series selector<\/div>\r\n    <h2>Set the column temperature. The series follows.<\/h2>\r\n    <p>Choose the temperature your reboiler, dryer or clean loop actually holds \u2014 not the maximum on a datasheet \u2014 and the panel returns the matching series, a realistic COP at that lift, the heat source that can feed it, and whether a boiler still has a job. Drag the slider or use the arrow keys. <strong>Most chemical and pharmaceutical heat sits in the first four bands, from 30 \u00b0C to 110 \u00b0C.<\/strong> The scale runs to 150 \u00b0C because low-pressure steam is real \u2014 and because where it stops, a fired heater or a validated clean-steam system takes over.<\/p>\r\n  <\/div>\r\n\r\n  <div class=\"tstage\">\r\n    <div class=\"tslider-wrap\">\r\n      <label for=\"tempSlider\" style=\"position:absolute;left:-9999px\">Select process temperature<\/label>\r\n      <input type=\"range\" class=\"tslider\" id=\"tempSlider\" min=\"30\" max=\"150\" step=\"1\" value=\"80\"\r\n             aria-describedby=\"tReadout\" aria-valuetext=\"80 degrees Celsius, drying and clean hot water series\">\r\n      <div class=\"ticks\">\r\n        <span style=\"left:0%\"><b>30<\/b>\u00b0C<\/span>\r\n        <span style=\"left:25%\"><b>60<\/b>\u00b0C<\/span>\r\n        <span style=\"left:41.7%\"><b>80<\/b>\u00b0C<\/span>\r\n        <span style=\"left:54.2%\"><b>95<\/b>\u00b0C<\/span>\r\n        <span style=\"left:66.7%\"><b>110<\/b>\u00b0C<\/span>\r\n        <span style=\"left:83.3%\"><b>130<\/b>\u00b0C<\/span>\r\n        <span style=\"left:100%\"><b>150<\/b>\u00b0C<\/span>\r\n      <\/div>\r\n    <\/div>\r\n\r\n    <div class=\"treadout\" id=\"tReadout\" aria-live=\"polite\">\r\n      <div class=\"tbig\">\r\n        <div class=\"lab\">Process temperature<\/div>\r\n        <div class=\"val\" id=\"tVal\">80<small>\u00b0C<\/small><\/div>\r\n        <div class=\"tseriesname\" id=\"tSeries\">Drying &amp; clean hot water<\/div>\r\n      <\/div>\r\n      <div class=\"tbody\">\r\n        <h4 id=\"tProcess\">Wet granules, tablets, API drying, CIP and wash water \u2014 60 \/ 80 \u00b0C<\/h4>\r\n        <p id=\"tDesc\">Pharmaceutical drying is deliberately gentle: wet granules 60\u201380 \u00b0C, coated tablets lower, API often below 90 \u00b0C to protect actives. The exhaust is warm and moist, so a dehumidifying heat pump recovers its latent heat and shortens the cycle. CIP wash water and WFI preheat are steady water loops that can share the same machine through a buffer tank.<\/p>\r\n        <div class=\"tspecs\">\r\n          <div class=\"tspec\"><b id=\"tCop\">3.9 \u2013 4.6<\/b><span>Typical COP<\/span><\/div>\r\n          <div class=\"tspec\"><b id=\"tDuty\">Dehumidified hot air \/ hot water<\/b><span>Delivery form<\/span><\/div>\r\n          <div class=\"tspec\"><b id=\"tSrc\">Dryer exhaust, cooling water<\/b><span>Feasible heat source<\/span><\/div>\r\n          <div class=\"tspec\"><b id=\"tBoiler\">No<\/b><span>Boiler still needed?<\/span><\/div>\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <div class=\"tcards\" id=\"tCards\">\r\n    <div class=\"tcards-h\">The six series \u2014 click a card to jump the slider<\/div>\r\n    <noscript>\r\n      <div class=\"series active\"><div class=\"sn\">01<\/div><div class=\"st\">30 \/ 60 \u00b0C<\/div><div class=\"sl\">Cooling-water heat &amp; clean utilities<\/div><p>Reactor cooling, condensers, WFI preheat, HVAC. COP 4.6\u20135.2.<\/p><\/div>\r\n      <div class=\"series\"><div class=\"sn\">02<\/div><div class=\"st\">60 \/ 80 \u00b0C<\/div><div class=\"sl\">Drying &amp; clean hot water<\/div><p>Granules, tablets, API, CIP and wash water. COP 3.9\u20134.6.<\/p><\/div>\r\n      <div class=\"series\"><div class=\"sn\">03<\/div><div class=\"st\">80 \/ 95 \u00b0C<\/div><div class=\"sl\">Vacuum separation &amp; extraction<\/div><p>Vacuum reboilers, evaporators, hot WFI. COP 3.4\u20133.9.<\/p><\/div>\r\n      <div class=\"series\"><div class=\"sn\">04<\/div><div class=\"st\">95 \/ 110 \u00b0C<\/div><div class=\"sl\">Solvent recovery &amp; reaction heat<\/div><p>Solvent columns, jackets, crystallisers. COP 3.0\u20133.4.<\/p><\/div>\r\n      <div class=\"series\"><div class=\"sn\">05<\/div><div class=\"st\">110 \/ 130 \u00b0C<\/div><div class=\"sl\">Low-pressure process steam<\/div><p>Reactors, kettles, reboilers, condensate return. COP 2.5\u20133.0.<\/p><\/div>\r\n      <div class=\"series\"><div class=\"sn\">06<\/div><div class=\"st\">130 \/ 150 \u00b0C<\/div><div class=\"sl\">High-temperature steam &amp; MVR<\/div><p>High-rate reboilers, hybrid steam. COP 2.0\u20132.5.<\/p><\/div>\r\n    <\/noscript>\r\n  <\/div>\r\n<\/section>\r\n\r\n<h2 id=\"estate\">One site, four heat loads<\/h2>\r\n  <p>A chemical or pharmaceutical site does not have one heat demand. It has a separation train that boils and condenses, a drying line that evaporates water or solvent, clean utilities that need hot water and steam, and a cooling system quietly rejecting the heat the first three need. On a continuous site these loads often run at the same time \u2014 which is exactly why the operating year, not the nameplate kW, is where the capital gets carried.<\/p>\r\n\r\n  <div class=\"cards c4\">\r\n    <div class=\"card\"><span class=\"num\">01<\/span><h4>Separation<\/h4><p>Reboilers 80\u2013130 \u00b0C, vacuum columns 60\u201395 \u00b0C, evaporator effects 70\u2013120 \u00b0C. The condenser at the top of the same column is the heat source for the bottom.<\/p><\/div>\r\n    <div class=\"card\"><span class=\"num\">02<\/span><h4>Drying &amp; evaporation<\/h4><p>Wet granules 60\u201380 \u00b0C, API and intermediates 50\u2013110 \u00b0C, spray-dryer support. The exhaust is warm and moist, so its latent heat is worth recovering.<\/p><\/div>\r\n    <div class=\"card\"><span class=\"num\">03<\/span><h4>Clean utilities<\/h4><p>CIP wash water 60\u201385 \u00b0C, WFI preheat 25\u201395 \u00b0C, humidification and cleanroom HVAC, low-pressure steam for non-product-contact duties.<\/p><\/div>\r\n    <div class=\"card\"><span class=\"num\">04<\/span><h4>Waste heat<\/h4><p>Reactor cooling water 40\u201390 \u00b0C, condenser heat 35\u201360 \u00b0C, hot condensate and effluent 50\u201395 \u00b0C, chiller condenser 30\u201340 \u00b0C. It leaves the site today; it is the fuel.<\/p><\/div>\r\n  <\/div>\r\n\r\n  <div class=\"note warn\">\r\n    <b class=\"lbl\">The number that decides a chemical project<\/b>\r\n    Not peak kW. Not nameplate COP. <strong>Whether a steady source and a steady sink exist at the same hours.<\/strong> A batch reactor that dumps heat for ninety minutes and a dryer that runs twenty hours a day are only a match if a buffer tank sits between them. Size the buffer before you size the machine \u2014 and remember that on a continuous site the hours are already in your favour.\r\n  <\/div>\r\n\r\n  <section class=\"finder\" id=\"finder\">\r\n    <div class=\"finder-head\">\r\n      <div class=\"kicker\">Process index<\/div>\r\n      <h2>Twenty-one unit operations, band by band<\/h2>\r\n      <p>The selector above answers one question \u2014 what series does this temperature need. This index answers the other: which real chemical and pharmaceutical steps sit in each band, what form of heat they want, and which machine serves them. Filter by band, or read the whole list. Sterilising autoclaves appear here as a boundary, not as a heat-pump duty.<\/p>\r\n    <\/div>\r\n    <div class=\"chips\" role=\"group\" aria-label=\"Filter processes by temperature band\">\r\n      <button class=\"chip\" data-band=\"all\" aria-pressed=\"true\">All processes<\/button>\r\n      <button class=\"chip\" data-band=\"1\" aria-pressed=\"false\">\u2264 60 \u00b0C<\/button>\r\n      <button class=\"chip\" data-band=\"2\" aria-pressed=\"false\">61\u201380 \u00b0C<\/button>\r\n      <button class=\"chip\" data-band=\"3\" aria-pressed=\"false\">81\u201395 \u00b0C<\/button>\r\n      <button class=\"chip\" data-band=\"4\" aria-pressed=\"false\">96\u2013110 \u00b0C<\/button>\r\n      <button class=\"chip\" data-band=\"5\" aria-pressed=\"false\">111\u2013130 \u00b0C<\/button>\r\n      <button class=\"chip\" data-band=\"6\" aria-pressed=\"false\">131\u2013150 \u00b0C<\/button>\r\n    <\/div>\r\n    <div class=\"pf-grid\" id=\"pfGrid\">\r\n      <div class=\"pfind-item\" data-band=\"1\"><div class=\"pf-top\"><b>Reactor cooling water<\/b><span class=\"pill p-hi\">Recovery<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">40\u201390 \u00b0C<\/span><span class=\"v\">\u00b7 exothermic batches, every campaign<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"1\"><div class=\"pf-top\"><b>Vacuum distillation condenser<\/b><span class=\"pill p-hi\">Recovery<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">35\u201355 \u00b0C<\/span><span class=\"v\">\u00b7 the other half of the reboiler pair<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"1\"><div class=\"pf-top\"><b>Chiller \/ refrigeration condenser<\/b><span class=\"pill p-hi\">Recovery<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">30\u201340 \u00b0C<\/span><span class=\"v\">\u00b7 rejected all summer, every year<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"1\"><div class=\"pf-top\"><b>WFI \/ purified water preheat<\/b><span class=\"pill p-mid\">Clean utility<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">25\u201345 \u00b0C<\/span><span class=\"v\">\u00b7 steady, low-grade, no product contact<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"1\"><div class=\"pf-top\"><b>Bioreactor \/ fermentation jacket<\/b><span class=\"pill p-mid\">Process<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">30\u201340 \u00b0C<\/span><span class=\"v\">\u00b7 tight control, long campaign<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"1\"><div class=\"pf-top\"><b>Cleanroom HVAC &amp; humidification<\/b><span class=\"pill p-hi\">Building<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">18\u201326 \u00b0C<\/span><span class=\"v\">\u00b7 continuous, often 8,000 h\/yr<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-A2W \u00b7 MT-A2A<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"2\"><div class=\"pf-top\"><b>Wet-granule drying (tablets)<\/b><span class=\"pill p-mid\">Drying<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">60\u201380 \u00b0C<\/span><span class=\"v\">\u00b7 higher risks actives and binders<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-A2A dehumidifying<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"2\"><div class=\"pf-top\"><b>CIP \/ wash-down water<\/b><span class=\"pill p-hi\">Clean utility<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">60\u201385 \u00b0C<\/span><span class=\"v\">\u00b7 cleaning validation sets the loop<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"2\"><div class=\"pf-top\"><b>Solvent extraction heating<\/b><span class=\"pill p-ind\">Separation<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">60\u201380 \u00b0C<\/span><span class=\"v\">\u00b7 solvent sets materials and Ex rating<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"2\"><div class=\"pf-top\"><b>Hot effluent heat recovery<\/b><span class=\"pill p-hi\">Recovery<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">50\u201380 \u00b0C<\/span><span class=\"v\">\u00b7 often the largest untapped stream<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"3\"><div class=\"pf-top\"><b>Vacuum distillation reboiler<\/b><span class=\"pill p-ind\">Separation<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">80\u201395 \u00b0C<\/span><span class=\"v\">\u00b7 pair it with its own condenser<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">HT-A2W \u00b7 MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"3\"><div class=\"pf-top\"><b>Multi-effect evaporator, first effects<\/b><span class=\"pill p-ind\">Separation<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">85\u201395 \u00b0C<\/span><span class=\"v\">\u00b7 MVR may beat both options<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">HT-A2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"3\"><div class=\"pf-top\"><b>Liquid pharma pasteurisation<\/b><span class=\"pill p-mid\">Process<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">72\u201385 \u00b0C<\/span><span class=\"v\">\u00b7 recover heat from the hot product<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"3\"><div class=\"pf-top\"><b>Extraction \/ concentration<\/b><span class=\"pill p-ind\">Separation<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">80\u201395 \u00b0C<\/span><span class=\"v\">\u00b7 botanical and API streams<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">HT-A2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"3\"><div class=\"pf-top\"><b>Hot WFI loop \/ sterile water<\/b><span class=\"pill p-mid\">Clean utility<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">80\u201395 \u00b0C<\/span><span class=\"v\">\u00b7 sanitisation cycle sets the peak<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">MT-W2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"4\"><div class=\"pf-top\"><b>Solvent recovery column<\/b><span class=\"pill p-ind\">Separation<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">95\u2013110 \u00b0C<\/span><span class=\"v\">\u00b7 condenser at 40\u201360 \u00b0C is the source<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">HT-A2W \u00b7 HT-W2S<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"4\"><div class=\"pf-top\"><b>Reaction jacket hot water<\/b><span class=\"pill p-ind\">Process<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">95\u2013110 \u00b0C<\/span><span class=\"v\">\u00b7 batch ramp, buffer recommended<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">HT-A2W<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"4\"><div class=\"pf-top\"><b>Crystalliser \/ evaporator heating<\/b><span class=\"pill p-ind\">Separation<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">96\u2013110 \u00b0C<\/span><span class=\"v\">\u00b7 close temperature approach needed<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">HT-A2W \u00b7 HT-W2S<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"5\"><div class=\"pf-top\"><b>Low-pressure reactor \/ kettle steam<\/b><span class=\"pill p-ind\">Steam<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">110\u2013130 \u00b0C<\/span><span class=\"v\">\u00b7 condensate must return<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">HT-W2S \u00b7 HT-A2S<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"5\"><div class=\"pf-top\"><b>Autoclave clean steam 121 \u00b0C<\/b><span class=\"pill p-lo\">Boundary<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">121 \u00b0C saturated<\/span><span class=\"v\">\u00b7 validated vessel \u2014 see clean-steam section<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">Clean-steam generator<\/span><\/div><\/div>\r\n      <div class=\"pfind-item\" data-band=\"6\"><div class=\"pf-top\"><b>High-temperature reboiler \/ MVR<\/b><span class=\"pill p-lo\">Hybrid<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Temp<\/span><span class=\"pf-temp\">130\u2013150 \u00b0C<\/span><span class=\"v\">\u00b7 top of the commercial range<\/span><\/div><div class=\"pf-row\"><span class=\"k\">Series<\/span><span class=\"v\">HT-W2S \u00b7 HT-A2S<\/span><\/div><\/div>\r\n    <\/div>\r\n    <div class=\"pf-sum\" id=\"pfSum\">Showing 21 unit operations across separation, drying, clean utilities and heat recovery.<\/div>\r\n  <\/section>\r\n\r\n\r\n\r\n  <!-- ============ ON THE PLANT ============ -->\r\n  <h2 id=\"plant\">On the plant: the column is a heat engine<\/h2>\r\n  <p>A distillation column boils at the bottom and condenses at the top. That is a heat pump in all but name \u2014 except most plants burn gas to make the reboiler heat and then spend cooling water to throw away the condenser heat. A mechanically driven heat pump closes that loop: take the 40\u201360 \u00b0C condenser heat, lift it to 95\u2013130 \u00b0C, and put it back into the reboiler. The same logic applies to evaporators, dryers and reactor jackets.<\/p>\r\n\r\n  <figure>\r\n    <div class=\"figbox\">\r\n      <svg viewBox=\"0 0 1160 430\" role=\"img\" aria-label=\"Chemical plant heat recovery diagram: distillation condenser, reactor cooling water and hot effluent feed a heat pump that supplies a reboiler, a dryer and clean utilities, with high-temperature reactor heat left on the fired heater\">\r\n        <defs>\r\n          <marker id=\"fa\" markerWidth=\"9\" markerHeight=\"9\" refX=\"7\" refY=\"3.5\" orient=\"auto\"><path d=\"M0 0 L0 7 L8 3.5 z\" fill=\"#4A3236\"\/><\/marker>\r\n          <marker id=\"faa\" markerWidth=\"9\" markerHeight=\"9\" refX=\"7\" refY=\"3.5\" orient=\"auto\"><path d=\"M0 0 L0 7 L8 3.5 z\" fill=\"#E60012\"\/><\/marker>\r\n        <\/defs>\r\n        <rect width=\"1160\" height=\"430\" fill=\"#FFFFFF\"\/>\r\n        <text class=\"fg-s\" x=\"30\" y=\"30\">The site as one heat system \u2014 rejected heat on the left, useful heat on the right<\/text>\r\n        <line class=\"fg-line\" x1=\"30\" y1=\"42\" x2=\"1130\" y2=\"42\"\/>\r\n\r\n        <rect class=\"fg-box\" x=\"30\" y=\"70\" width=\"230\" height=\"88\" rx=\"8\"\/>\r\n        <text class=\"fg-tb\" x=\"145\" y=\"96\" text-anchor=\"middle\">Distillation condenser<\/text>\r\n        <text class=\"fg-s\" x=\"145\" y=\"117\" text-anchor=\"middle\">Vacuum \/ atmospheric, 35\u201360 \u00b0C<\/text>\r\n        <text class=\"fg-a\" x=\"145\" y=\"140\" text-anchor=\"middle\">The other half of the reboiler pair<\/text>\r\n\r\n        <rect class=\"fg-box\" x=\"30\" y=\"172\" width=\"230\" height=\"88\" rx=\"8\"\/>\r\n        <text class=\"fg-tb\" x=\"145\" y=\"198\" text-anchor=\"middle\">Reactor cooling water<\/text>\r\n        <text class=\"fg-s\" x=\"145\" y=\"219\" text-anchor=\"middle\">Exothermic batches, 40\u201390 \u00b0C<\/text>\r\n        <text class=\"fg-a\" x=\"145\" y=\"242\" text-anchor=\"middle\">Removed by cooling tower today<\/text>\r\n\r\n        <rect class=\"fg-box\" x=\"30\" y=\"274\" width=\"230\" height=\"88\" rx=\"8\"\/>\r\n        <text class=\"fg-tb\" x=\"145\" y=\"300\" text-anchor=\"middle\">Hot condensate &amp; effluent<\/text>\r\n        <text class=\"fg-s\" x=\"145\" y=\"321\" text-anchor=\"middle\">50\u201395 \u00b0C, continuous<\/text>\r\n        <text class=\"fg-a\" x=\"145\" y=\"344\" text-anchor=\"middle\">Often the largest untapped stream<\/text>\r\n\r\n        <rect x=\"335\" y=\"135\" width=\"245\" height=\"190\" rx=\"10\" fill=\"#170A0C\"\/>\r\n        <text class=\"fg-tw\" x=\"457\" y=\"167\" text-anchor=\"middle\">HETAPRO heat pump<\/text>\r\n        <text class=\"fg-sw\" x=\"457\" y=\"191\" text-anchor=\"middle\">MT-W2W \/ HT-A2W \/ HT-W2S<\/text>\r\n        <line x1=\"362\" y1=\"207\" x2=\"552\" y2=\"207\" stroke=\"#4A3236\"\/>\r\n        <text class=\"fg-sw\" x=\"457\" y=\"231\" text-anchor=\"middle\">Evaporator \u2190 35\u201390 \u00b0C<\/text>\r\n        <text class=\"fg-sw\" x=\"457\" y=\"253\" text-anchor=\"middle\">Condenser \u2192 80\u2013150 \u00b0C<\/text>\r\n        <text class=\"fg-sw\" x=\"457\" y=\"281\" text-anchor=\"middle\">Buffer decouples batch timing<\/text>\r\n        <text class=\"fg-sw\" x=\"457\" y=\"303\" text-anchor=\"middle\">Refrigerant stays in the machine<\/text>\r\n\r\n        <rect class=\"fg-box-a\" x=\"660\" y=\"60\" width=\"230\" height=\"86\" rx=\"8\"\/>\r\n        <text class=\"fg-t\" x=\"775\" y=\"86\" text-anchor=\"middle\">Reboiler \/ column<\/text>\r\n        <text class=\"fg-s\" x=\"775\" y=\"107\" text-anchor=\"middle\">95\u2013130 \u00b0C hot water or steam<\/text>\r\n        <text class=\"fg-al\" x=\"775\" y=\"129\" text-anchor=\"middle\">Low-pressure steam is enough<\/text>\r\n\r\n        <rect class=\"fg-box-a\" x=\"660\" y=\"158\" width=\"230\" height=\"86\" rx=\"8\"\/>\r\n        <text class=\"fg-t\" x=\"775\" y=\"184\" text-anchor=\"middle\">Dryer \/ evaporator<\/text>\r\n        <text class=\"fg-s\" x=\"775\" y=\"205\" text-anchor=\"middle\">60\u2013110 \u00b0C air or hot water<\/text>\r\n        <text class=\"fg-al\" x=\"775\" y=\"227\" text-anchor=\"middle\">Granules, API, solvent recovery<\/text>\r\n\r\n        <rect class=\"fg-box-a\" x=\"660\" y=\"256\" width=\"230\" height=\"86\" rx=\"8\"\/>\r\n        <text class=\"fg-t\" x=\"775\" y=\"282\" text-anchor=\"middle\">Clean utilities<\/text>\r\n        <text class=\"fg-s\" x=\"775\" y=\"303\" text-anchor=\"middle\">60\u201395 \u00b0C CIP, WFI preheat, HVAC<\/text>\r\n        <text class=\"fg-al\" x=\"775\" y=\"325\" text-anchor=\"middle\">Steady, non-product-contact<\/text>\r\n\r\n        <rect x=\"930\" y=\"158\" width=\"200\" height=\"86\" rx=\"8\" fill=\"#FDF3E7\" stroke=\"#B45309\" stroke-width=\"1.4\"\/>\r\n        <text class=\"fg-t\" x=\"1030\" y=\"184\" text-anchor=\"middle\">Reactor &gt;180 \u00b0C<\/text>\r\n        <text class=\"fg-s\" x=\"1030\" y=\"205\" text-anchor=\"middle\">High-temperature synthesis<\/text>\r\n        <text class=\"fg-al\" x=\"1030\" y=\"227\" text-anchor=\"middle\">Fired heater stays<\/text>\r\n\r\n        <g class=\"fg-arrow\">\r\n          <path d=\"M260 114 H300 V180 H331\"\/>\r\n          <path d=\"M260 216 H331\"\/>\r\n          <path d=\"M260 318 H300 V255 H331\"\/>\r\n        <\/g>\r\n        <g class=\"fg-arrow-a\">\r\n          <path d=\"M580 175 H620 V103 H656\"\/>\r\n          <path d=\"M580 205 H656\"\/>\r\n          <path d=\"M580 235 H620 V299 H656\"\/>\r\n        <\/g>\r\n        <line class=\"fg-dash\" x1=\"890\" y1=\"201\" x2=\"926\" y2=\"201\"\/>\r\n        <text class=\"fg-s\" x=\"30\" y=\"405\">Dotted line: the high-temperature reactor is a hybrid duty. The heat pump can preheat its feed; it cannot replace the fired heater.<\/text>\r\n      <\/svg>\r\n    <\/div>\r\n    <figcaption><b>Figure 1 \u2014 The plant heat loop.<\/b> The three sources on the left already exist on a chemical site. The heat pump does not create heat; it moves it to the temperature each unit operation needs. One buffer tank lets a batch exotherm feed a continuous reboiler \u2014 provided the two loads actually overlap over the year.<\/figcaption>\r\n  <\/figure>\r\n\r\n  <h3>Distillation and evaporation: match the condenser to the reboiler<\/h3>\r\n  <p>The reboiler and condenser of one column sit 40\u201370 K apart. That is exactly the lift a cascade heat pump is built for, and it is why distillation is the most natural heat-pump integration in the chemical industry. Published projects now reach 150 \u00b0C and above: a 50 MW thermal unit at BASF's Ludwigshafen site supplies formic-acid steam from steam-cracker waste heat, while a pharmaceutical installation in Sweden uses a 500 kW heat pump to deliver steam at 10 bar.<\/p>\r\n  <div class=\"cards c2\">\r\n    <div class=\"card\"><h4>Start with the boiling pair, not the machine<\/h4><p>Map the condenser and reboiler of each column as a pair before you look at any datasheet. A vacuum column with a 35\u201355 \u00b0C condenser and an 80\u201395 \u00b0C reboiler is an excellent fit at COP 3.4\u20133.9. An atmospheric column needing 130 \u00b0C is a different case, with COP closer to 2.5 and a much tighter need for close source heat.<\/p><\/div>\r\n    <div class=\"card\"><h4>Know when MVR is the better tool<\/h4><p>For a single-effect evaporator with a small boiling-point elevation, mechanical vapour recompression is often the cheapest route. Heat pumps and MVR are not rivals: the heat pump can preheat the feed, MVR compresses the vapour, and a boiler keeps a small trim duty. Ask for both options priced in the same study.<\/p><\/div>\r\n  <\/div>\r\n\r\n  <h3>Drying and clean utilities: low temperature, high hygiene<\/h3>\r\n  <p>Pharmaceutical drying is deliberately gentle \u2014 wet granules at 60\u201380 \u00b0C, coated tablets lower, API often below 90 \u00b0C to protect actives. The exhaust is warm and moist, so a dehumidifying heat pump recovers latent heat and shortens the cycle. CIP and WFI preheat are steady water loads that can share the same loop, and cleanroom HVAC is often the longest-running duty on the site.<\/p>\r\n  <div class=\"tbl-wrap\">\r\n    <table>\r\n      <caption>Indicative drying and utility windows \u2014 the product and the validated process set the ceiling, not the machine.<\/caption>\r\n      <thead><tr><th>Duty<\/th><th>Temperature<\/th><th>What limits it<\/th><th>Heat form<\/th><\/tr><\/thead>\r\n      <tbody>\r\n        <tr><td><strong>Wet granulation (tablets)<\/strong><\/td><td class=\"num\">60\u201380 \u00b0C<\/td><td>Actives, binders and starch gelatinisation<\/td><td>Dehumidified hot air<\/td><\/tr>\r\n        <tr><td><strong>Fluid-bed \/ coating<\/strong><\/td><td class=\"num\">50\u201380 \u00b0C<\/td><td>Product-bed uniformity and solvent limits<\/td><td>Dehumidified hot air<\/td><\/tr>\r\n        <tr><td><strong>API \/ intermediates<\/strong><\/td><td class=\"num\">50\u2013110 \u00b0C<\/td><td>Thermal and solvent stability<\/td><td>Hot air \/ hot water coil<\/td><\/tr>\r\n        <tr><td><strong>Lyophiliser support<\/strong><\/td><td class=\"num\">30\u201360 \u00b0C<\/td><td>Shelf and condenser heat; vacuum is the process<\/td><td>Hot water<\/td><\/tr>\r\n        <tr><td><strong>CIP \/ wash water<\/strong><\/td><td class=\"num\">60\u201385 \u00b0C<\/td><td>Cleaning validation, not temperature alone<\/td><td>Hot water<\/td><\/tr>\r\n        <tr><td><strong>WFI preheat \/ hot loop<\/strong><\/td><td class=\"num\">25\u201395 \u00b0C<\/td><td>Loop temperature and sanitisation cycle<\/td><td>Hot water<\/td><\/tr>\r\n      <\/tbody>\r\n    <\/table>\r\n  <\/div>\r\n\r\n  <div class=\"note deep\">\r\n    <b class=\"lbl\">Drying rate is not machine capacity<\/b>\r\n    Drying is a mass-transfer problem. A kW rating tells you how fast the machine heats air; the water removal rate tells you how fast the batch dries. Ask for <strong>kg of water removed per hour at your inlet humidity and target moisture<\/strong> \u2014 figures quoted on a dry-air day do not transfer to a humid production week. Published heat-pump dryers commonly report 1\u20132 kg\/kWh specific moisture extraction.\r\n  <\/div>\r\n\r\n  <!-- ============ CLEAN STEAM ============ -->\r\n  <h2 id=\"clean-steam\">Clean steam and the validated boundary<\/h2>\r\n  <p>This is the line that matters in pharma. A sterilising autoclave runs at 121 \u00b0C for 20 minutes or 134 \u00b0C for 5 minutes, with saturated steam, controlled air removal, defined steam quality and IQ\/OQ\/PQ records. It is a validated pressure vessel, not a heat-pump duty in the same sense as a reboiler. The heat pump's job is upstream: preheat boiler feedwater, carry the utility hot-water loop, and feed the clean-steam generator's primary side through a double tube-sheet exchanger. The clean side stays exactly as validated; refrigerant never comes near it.<\/p>\r\n\r\n  <figure>\r\n    <div class=\"figbox\">\r\n      <svg viewBox=\"0 0 1160 400\" role=\"img\" aria-label=\"Clean steam boundary diagram: condenser and cooling water feed a heat pump that serves feedwater preheat, a clean steam generator primary side and utility reboilers, while the validated autoclave remains on the clean steam generator\">\r\n        <defs>\r\n          <marker id=\"fa2\" markerWidth=\"9\" markerHeight=\"9\" refX=\"7\" refY=\"3.5\" orient=\"auto\"><path d=\"M0 0 L0 7 L8 3.5 z\" fill=\"#4A3236\"\/><\/marker>\r\n          <marker id=\"faa2\" markerWidth=\"9\" markerHeight=\"9\" refX=\"7\" refY=\"3.5\" orient=\"auto\"><path d=\"M0 0 L0 7 L8 3.5 z\" fill=\"#E60012\"\/><\/marker>\r\n        <\/defs>\r\n        <rect width=\"1160\" height=\"400\" fill=\"#FFFFFF\"\/>\r\n        <text class=\"fg-s\" x=\"30\" y=\"30\">The clean-steam line \u2014 the heat pump stops at the primary side of the exchanger<\/text>\r\n        <line class=\"fg-line\" x1=\"30\" y1=\"42\" x2=\"1130\" y2=\"42\"\/>\r\n\r\n        <rect class=\"fg-box\" x=\"30\" y=\"80\" width=\"235\" height=\"100\" rx=\"8\"\/>\r\n        <text class=\"fg-tb\" x=\"147\" y=\"106\" text-anchor=\"middle\">Column condenser<\/text>\r\n        <text class=\"fg-s\" x=\"147\" y=\"127\" text-anchor=\"middle\">Cooling water, hot condensate<\/text>\r\n        <text class=\"fg-a\" x=\"147\" y=\"153\" text-anchor=\"middle\">35\u201390 \u00b0C, continuous<\/text>\r\n\r\n        <rect class=\"fg-box\" x=\"30\" y=\"205\" width=\"235\" height=\"100\" rx=\"8\"\/>\r\n        <text class=\"fg-tb\" x=\"147\" y=\"231\" text-anchor=\"middle\">Utility steam demand<\/text>\r\n        <text class=\"fg-s\" x=\"147\" y=\"252\" text-anchor=\"middle\">Reboilers, jackets, dryers<\/text>\r\n        <text class=\"fg-a\" x=\"147\" y=\"278\" text-anchor=\"middle\">Base load the boiler carries today<\/text>\r\n\r\n        <rect x=\"340\" y=\"130\" width=\"240\" height=\"170\" rx=\"10\" fill=\"#170A0C\"\/>\r\n        <text class=\"fg-tw\" x=\"460\" y=\"162\" text-anchor=\"middle\">HETAPRO heat pump<\/text>\r\n        <text class=\"fg-sw\" x=\"460\" y=\"186\" text-anchor=\"middle\">HT-A2W \/ HT-W2S<\/text>\r\n        <line x1=\"367\" y1=\"202\" x2=\"553\" y2=\"202\" stroke=\"#4A3236\"\/>\r\n        <text class=\"fg-sw\" x=\"460\" y=\"226\" text-anchor=\"middle\">Evaporator \u2190 35\u201390 \u00b0C<\/text>\r\n        <text class=\"fg-sw\" x=\"460\" y=\"248\" text-anchor=\"middle\">Condenser \u2192 95\u2013150 \u00b0C<\/text>\r\n        <text class=\"fg-sw\" x=\"460\" y=\"276\" text-anchor=\"middle\">One lift, several utility loops<\/text>\r\n\r\n        <rect class=\"fg-box-a\" x=\"665\" y=\"70\" width=\"225\" height=\"80\" rx=\"8\"\/>\r\n        <text class=\"fg-t\" x=\"777\" y=\"96\" text-anchor=\"middle\">Feedwater preheat<\/text>\r\n        <text class=\"fg-s\" x=\"777\" y=\"117\" text-anchor=\"middle\">60\u201395 \u00b0C hot water<\/text>\r\n        <text class=\"fg-al\" x=\"777\" y=\"137\" text-anchor=\"middle\">Cuts fuel before the boiler<\/text>\r\n\r\n        <rect class=\"fg-box-a\" x=\"665\" y=\"165\" width=\"225\" height=\"80\" rx=\"8\"\/>\r\n        <text class=\"fg-t\" x=\"777\" y=\"191\" text-anchor=\"middle\">Clean-steam generator<\/text>\r\n        <text class=\"fg-s\" x=\"777\" y=\"212\" text-anchor=\"middle\">Primary side, double tube sheet<\/text>\r\n        <text class=\"fg-al\" x=\"777\" y=\"232\" text-anchor=\"middle\">Clean side unchanged<\/text>\r\n\r\n        <rect class=\"fg-box-a\" x=\"665\" y=\"260\" width=\"225\" height=\"80\" rx=\"8\"\/>\r\n        <text class=\"fg-t\" x=\"777\" y=\"286\" text-anchor=\"middle\">Reboilers &amp; dryers<\/text>\r\n        <text class=\"fg-s\" x=\"777\" y=\"307\" text-anchor=\"middle\">95\u2013130 \u00b0C low-pressure steam<\/text>\r\n        <text class=\"fg-al\" x=\"777\" y=\"327\" text-anchor=\"middle\">Non-product-contact duties<\/text>\r\n\r\n        <rect x=\"930\" y=\"165\" width=\"200\" height=\"80\" rx=\"8\" fill=\"#FDF3E7\" stroke=\"#B45309\" stroke-width=\"1.4\"\/>\r\n        <text class=\"fg-t\" x=\"1030\" y=\"191\" text-anchor=\"middle\">Autoclave<\/text>\r\n        <text class=\"fg-s\" x=\"1030\" y=\"212\" text-anchor=\"middle\">121 \/ 134 \u00b0C saturated<\/text>\r\n        <text class=\"fg-al\" x=\"1030\" y=\"232\" text-anchor=\"middle\">Validated \u2014 stays put<\/text>\r\n\r\n        <g class=\"fg-arrow\">\r\n          <path d=\"M265 130 H300 V200 H336\"\/>\r\n          <path d=\"M265 255 H300 V235 H336\"\/>\r\n        <\/g>\r\n        <g class=\"fg-arrow-a\">\r\n          <path d=\"M580 170 H620 V110 H661\"\/>\r\n          <path d=\"M580 205 H661\"\/>\r\n          <path d=\"M580 245 H620 V300 H661\"\/>\r\n        <\/g>\r\n        <line class=\"fg-dash\" x1=\"890\" y1=\"205\" x2=\"926\" y2=\"205\"\/>\r\n        <text class=\"fg-s\" x=\"30\" y=\"375\">Dotted line: the autoclave is a pressure boundary and a validated process, not a temperature target. Re-qualifying it is not a heat-pump project.<\/text>\r\n      <\/svg>\r\n    <\/div>\r\n    <figcaption><b>Figure 2 \u2014 The clean-steam line.<\/b> The heat pump feeds the primary side only. The clean-steam generator, its double tube-sheet exchanger and the autoclave remain exactly as qualified \u2014 which is precisely why the project is approvable.<\/figcaption>\r\n  <\/figure>\r\n\r\n  <div class=\"note\">\r\n    <b class=\"lbl\">Not sure where your heat stops?<\/b>\r\n    If your heat ends at the column, the dryer and the utility loop, you are in the right place. If it ends in a food retort, CIP and UHT line, go to our <a class=\"plink\" href=\"https:\/\/hetapro.com\/industrial-high-temperature-heat-pumps-solutions-for-food-and-beverage-industry\/\" target=\"_blank\" rel=\"noopener\">Food &amp; Beverage solution guide<\/a>. If it is battery drying or wafer processing, go to our <a class=\"plink\" href=\"https:\/\/hetapro.com\/new-energy-electronics-heat-pump-solutions\/\" target=\"_blank\" rel=\"noopener\">New Energy &amp; Electronics guide<\/a>. All three use the same six machines; the split is by process step, not by customer.\r\n  <\/div>\r\n\r\n  <h2>Adjacent duties we also size<\/h2>\r\n  <div class=\"cards c4\">\r\n    <div class=\"card\"><h4>Solvent recovery<\/h4><p>Distillation columns at 80\u2013130 \u00b0C with condensers at 40\u201360 \u00b0C form one of the cleanest source-and-sink pairs on a chemical site. Ex-rated equipment and solvent-compatible materials are specified from the first conversation, not added later.<\/p><\/div>\r\n    <div class=\"card\"><h4>Biotech &amp; fermentation<\/h4><p>30\u201340 \u00b0C reactor jackets and 60\u201385 \u00b0C CIP loops, low-grade and continuous, often paired with chiller condenser heat. The clean utility boundary is straightforward because the heat never touches product.<\/p><\/div>\r\n    <div class=\"card\"><h4>Specialty chemicals<\/h4><p>Batch reactors at 60\u2013110 \u00b0C and hot effluent at 50\u201395 \u00b0C. A buffer tank turns a ninety-minute exotherm into an all-day heat source; without one the same site looks like a poor fit on paper.<\/p><\/div>\r\n    <div class=\"card\"><h4>Particle &amp; tableting<\/h4><p>50\u201385 \u00b0C dehumidified drying with tight humidity control, plus heat recovery from the dryer exhaust. The latent heat in that exhaust is usually larger than the sensible term.<\/p><\/div>\r\n  <\/div>\r\n\r\n  <div class=\"pshell\" id=\"products\">\r\n    <div class=\"pshell-head\">\r\n      <div class=\"kicker\">Product match<\/div>\r\n      <h2>Six series, matched to the process step<\/h2>\r\n      <p>Chemical and pharmaceutical sites use the whole range, but the case is strongest between 30 \u00b0C and 110&nbsp;\u00b0C, where the waste heat already exists. <strong>The cards outlined in red follow the temperature band currently selected in the selector above<\/strong> \u2014 change the slider and the recommendation changes with it.<\/p>\r\n    <\/div>\r\n    <div class=\"pshell-body\">\r\n      <div class=\"pgrid\" id=\"pGrid\">\r\n        <div class=\"pcard\" data-series=\"1,2,3\">\r\n          <div class=\"pcard-top\"><div class=\"pmodel\"><a class=\"plink\" href=\"https:\/\/hetapro.com\/products\/mt-a2w-95c-hot-water-scroll-heat-pump\/\" target=\"_blank\" rel=\"noopener\">MT-A2W<\/a><\/div><div class=\"ptag\">95 \u00b0C hot water \u00b7 air source<\/div><\/div>\r\n          <div class=\"pimg\"><a href=\"https:\/\/hetapro.com\/products\/mt-a2w-95c-hot-water-scroll-heat-pump\/\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/10\/1-mt-a2w.webp\" alt=\"MT-A2W air source 95\u00b0C hot water scroll heat pump unit\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\"><\/a><\/div>\r\n          <div class=\"pcard-body\">\r\n            <p>Utility hot water, cleanroom HVAC and CIP loops where no water-side waste heat is available.<\/p>\r\n            <div class=\"pspecs\">\r\n              <div class=\"pspec\"><b>95 \u00b0C<\/b><span>Max. water<\/span><\/div>\r\n              <div class=\"pspec\"><b>350 kW<\/b><span>Typical output<\/span><\/div>\r\n              <div class=\"pspec\"><b>Scroll<\/b><span>Compressor<\/span><\/div>\r\n              <div class=\"pspec\"><b>Air<\/b><span>Heat source<\/span><\/div>\r\n            <\/div>\r\n            <a class=\"pmore\" href=\"https:\/\/hetapro.com\/products\/mt-a2w-95c-hot-water-scroll-heat-pump\/\">MT-A2W product page \u2192<\/a>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div class=\"pcard\" data-series=\"1,2,3,4\">\r\n          <div class=\"pcard-top\"><div class=\"pmodel\"><a class=\"plink\" href=\"https:\/\/hetapro.com\/products\/mt-w2w-95c-hot-water-screw-heat-pump\/\" target=\"_blank\" rel=\"noopener\">MT-W2W<\/a><\/div><div class=\"ptag\">95 \u00b0C hot water \u00b7 water source<\/div><\/div>\r\n          <div class=\"pimg\"><a href=\"https:\/\/hetapro.com\/products\/mt-w2w-95c-hot-water-screw-heat-pump\/\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/10\/2-mt-w2w.webp\" alt=\"MT-W2W water source 95\u00b0C hot water screw heat pump unit\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\"><\/a><\/div>\r\n          <div class=\"pcard-body\">\r\n            <p>The site workhorse: reactor cooling water, distillation condensers and hot effluent become the source for the next loop.<\/p>\r\n            <div class=\"pspecs\">\r\n              <div class=\"pspec\"><b>95 \u00b0C<\/b><span>Max. water<\/span><\/div>\r\n              <div class=\"pspec\"><b>1,500 kW<\/b><span>Typical output<\/span><\/div>\r\n              <div class=\"pspec\"><b>Screw + VFD<\/b><span>Compressor<\/span><\/div>\r\n              <div class=\"pspec\"><b>Water<\/b><span>Heat source<\/span><\/div>\r\n            <\/div>\r\n            <a class=\"pmore\" href=\"https:\/\/hetapro.com\/products\/mt-w2w-95c-hot-water-screw-heat-pump\/\">MT-W2W product page \u2192<\/a>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div class=\"pcard\" data-series=\"3,4,5\">\r\n          <div class=\"pcard-top\"><div class=\"pmodel\"><a class=\"plink\" href=\"https:\/\/hetapro.com\/products\/ht-a2w-135c-hot-water-piston-heat-pump\/\" target=\"_blank\" rel=\"noopener\">HT-A2W<\/a><\/div><div class=\"ptag\">135 \u00b0C hot water \u00b7 air source<\/div><\/div>\r\n          <div class=\"pimg\"><a href=\"https:\/\/hetapro.com\/products\/ht-a2w-135c-hot-water-piston-heat-pump\/\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/10\/3-ht-a2w.webp\" alt=\"HT-A2W air source 135\u00b0C hot water piston heat pump unit\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\"><\/a><\/div>\r\n          <div class=\"pcard-body\">\r\n            <p>Vacuum-column reboilers, solvent recovery and reaction jackets above 95 \u00b0C where no water-side source is available.<\/p>\r\n            <div class=\"pspecs\">\r\n              <div class=\"pspec\"><b>135 \u00b0C<\/b><span>Max. water<\/span><\/div>\r\n              <div class=\"pspec\"><b>220 kW<\/b><span>Typical output<\/span><\/div>\r\n              <div class=\"pspec\"><b>Piston<\/b><span>Compressor<\/span><\/div>\r\n              <div class=\"pspec\"><b>Air<\/b><span>Heat source<\/span><\/div>\r\n            <\/div>\r\n            <a class=\"pmore\" href=\"https:\/\/hetapro.com\/products\/ht-a2w-135c-hot-water-piston-heat-pump\/\">HT-A2W product page \u2192<\/a>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div class=\"pcard\" data-series=\"4,5,6\">\r\n          <div class=\"pcard-top\"><div class=\"pmodel\"><a class=\"plink\" href=\"https:\/\/hetapro.com\/products\/ht-w2s-150c-steam-heat-pump\/\" target=\"_blank\" rel=\"noopener\">HT-W2S<\/a><\/div><div class=\"ptag\">110\u2013150 \u00b0C steam \u00b7 water source<\/div><\/div>\r\n          <div class=\"pimg\"><a href=\"https:\/\/hetapro.com\/products\/ht-w2s-150c-steam-heat-pump\/\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/10\/4.ht-w2s.webp\" alt=\"HT-W2S water source 150\u00b0C steam heat pump unit\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\"><\/a><\/div>\r\n          <div class=\"pcard-body\">\r\n            <p>Low-pressure steam for reactors, kettles and evaporators where the plant already returns condensate.<\/p>\r\n            <div class=\"pspecs\">\r\n              <div class=\"pspec\"><b>150 \u00b0C<\/b><span>Steam<\/span><\/div>\r\n              <div class=\"pspec\"><b>110\u2013150 \u00b0C<\/b><span>Range<\/span><\/div>\r\n              <div class=\"pspec\"><b>Screw<\/b><span>Compressor<\/span><\/div>\r\n              <div class=\"pspec\"><b>Water<\/b><span>Heat source<\/span><\/div>\r\n            <\/div>\r\n            <a class=\"pmore\" href=\"https:\/\/hetapro.com\/products\/ht-w2s-150c-steam-heat-pump\/\">HT-W2S product page \u2192<\/a>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div class=\"pcard\" data-series=\"5,6\">\r\n          <div class=\"pcard-top\"><div class=\"pmodel\"><a class=\"plink\" href=\"https:\/\/hetapro.com\/products\/ht-a2s-150c-steam-heat-pump\/\" target=\"_blank\" rel=\"noopener\">HT-A2S<\/a><\/div><div class=\"ptag\">110\u2013150 \u00b0C steam \u00b7 air source<\/div><\/div>\r\n          <div class=\"pimg\"><a href=\"https:\/\/hetapro.com\/products\/ht-a2s-150c-steam-heat-pump\/\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/10\/5.ht-a2s.webp\" alt=\"HT-A2S air source 150\u00b0C steam heat pump unit\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\"><\/a><\/div>\r\n          <div class=\"pcard-body\">\r\n            <p>Sites with no usable water-side source that still need 110\u2013150 \u00b0C steam \u2014 warm exhaust or waste water is the source here.<\/p>\r\n            <div class=\"pspecs\">\r\n              <div class=\"pspec\"><b>150 \u00b0C<\/b><span>Steam<\/span><\/div>\r\n              <div class=\"pspec\"><b>110\u2013150 \u00b0C<\/b><span>Range<\/span><\/div>\r\n              <div class=\"pspec\"><b>Piston<\/b><span>Compressor<\/span><\/div>\r\n              <div class=\"pspec\"><b>Air<\/b><span>Heat source<\/span><\/div>\r\n            <\/div>\r\n            <a class=\"pmore\" href=\"https:\/\/hetapro.com\/products\/ht-a2s-150c-steam-heat-pump\/\">HT-A2S product page \u2192<\/a>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div class=\"pcard\" data-series=\"1,2,3\">\r\n          <div class=\"pcard-top\"><div class=\"pmodel\"><a class=\"plink\" href=\"https:\/\/hetapro.com\/products\/mt-a2a-85c-air-source-direct-heating-inverter-hot-air-heat-pump-dryer\/\" target=\"_blank\" rel=\"noopener\">MT-A2A<\/a><\/div><div class=\"ptag\">30\u201385 \u00b0C hot air \u00b7 inverter dryer<\/div><\/div>\r\n          <div class=\"pimg\"><a href=\"https:\/\/hetapro.com\/products\/mt-a2a-85c-air-source-direct-heating-inverter-hot-air-heat-pump-dryer\/\" target=\"_blank\" rel=\"noopener\"><img src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2026\/10\/6.mt-a2a.webp\" alt=\"MT-A2A air source inverter hot air heat pump dryer\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\"><\/a><\/div>\r\n          <div class=\"pcard-body\">\r\n            <p>Wet-granule, tablet and API drying: dehumidified hot air with inverter control, 30\u201385 \u00b0C.<\/p>\r\n            <div class=\"pspecs\">\r\n              <div class=\"pspec\"><b>30\u201385 \u00b0C<\/b><span>Air<\/span><\/div>\r\n              <div class=\"pspec\"><b>Direct<\/b><span>Heating<\/span><\/div>\r\n              <div class=\"pspec\"><b>Inverter<\/b><span>Compressor<\/span><\/div>\r\n              <div class=\"pspec\"><b>Air<\/b><span>Heat source<\/span><\/div>\r\n            <\/div>\r\n            <a class=\"pmore\" href=\"https:\/\/hetapro.com\/products\/mt-a2a-85c-air-source-direct-heating-inverter-hot-air-heat-pump-dryer\/\">MT-A2A product page \u2192<\/a>\r\n          <\/div>\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n<!-- ============ TOTAL COST OF OWNERSHIP ============ -->\r\n<section class=\"calc\" id=\"tco\">\r\n  <div class=\"calc-head\">\r\n    <div class=\"kicker\">Total cost of ownership<\/div>\r\n    <h3>Ten years of heat, priced on your operating year<\/h3>\r\n    <p>Energy price alone does not decide a chemical or pharma project \u2014 capital, load, source temperature and <strong>operating hours<\/strong> do. A continuous plant at 7,000 hours and a batch line at 3,000 are entirely different investments at the same kW. Set seven numbers and the panel prices both options over ten years, including the capital the boiler option does not need.<\/p>\r\n  <\/div>\r\n  <div class=\"calc-body\">\r\n    <div class=\"calc-in\">\r\n      <div class=\"fld\">\r\n        <label for=\"fuelPrice\">Fuel price per kWh of fuel input <b id=\"fuelPriceV\">0.050<\/b><\/label>\r\n        <input type=\"range\" id=\"fuelPrice\" min=\"0.010\" max=\"0.160\" step=\"0.002\" value=\"0.050\">\r\n        <div class=\"hint\">Delivered gas or fuel-oil cost divided by heating value. On a site that buys utility steam, use the steam tariff divided by boiler efficiency instead.<\/div>\r\n      <\/div>\r\n      <div class=\"fld\">\r\n        <label for=\"elecPrice\">Electricity price per kWh <b id=\"elecPriceV\">0.120<\/b><\/label>\r\n        <input type=\"range\" id=\"elecPrice\" min=\"0.03\" max=\"0.45\" step=\"0.005\" value=\"0.120\">\r\n        <div class=\"hint\">All-in industrial tariff, including demand charges. If you have a power purchase agreement or on-site generation, use the effective rate you actually pay.<\/div>\r\n      <\/div>\r\n      <div class=\"fld\">\r\n        <label for=\"boilerEff\">Boiler efficiency <b id=\"boilerEffV\">85 %<\/b><\/label>\r\n        <input type=\"range\" id=\"boilerEff\" min=\"45\" max=\"96\" step=\"1\" value=\"85\">\r\n        <div class=\"hint\">A well-maintained package boiler runs 82\u201388 %. An older site with poor feedwater treatment can be below 75 %. Be honest here \u2014 it changes the answer.<\/div>\r\n      <\/div>\r\n      <div class=\"fld\">\r\n        <label for=\"copSel\">COP at your duty point <b id=\"copSelV\">3.9<\/b><\/label>\r\n        <input type=\"range\" id=\"copSel\" min=\"1.5\" max=\"5.4\" step=\"0.1\" value=\"3.9\">\r\n        <div class=\"hint\">Synced to the selector above and deliberately moderate in the 61\u201380 \u00b0C band. Override it the moment you have a guaranteed figure at your own lift.<\/div>\r\n      <\/div>\r\n      <div class=\"fld\">\r\n        <label for=\"loadKw\">Average heat load <b id=\"loadKwV\">500 kW<\/b><\/label>\r\n        <input type=\"range\" id=\"loadKw\" min=\"100\" max=\"5000\" step=\"50\" value=\"500\">\r\n        <div class=\"hint\">Average over the hours you actually run, not the design-peak kW. The peak sizes the machine; the average sizes the saving.<\/div>\r\n      <\/div>\r\n      <div class=\"fld\">\r\n        <label for=\"runHours\">Annual operating hours <b id=\"runHoursV\">6,000 h<\/b><\/label>\r\n        <input type=\"range\" id=\"runHours\" min=\"400\" max=\"8760\" step=\"100\" value=\"6000\">\r\n        <div class=\"hint\">Continuous chemical plants 6,000\u20138,000 h. Batch pharma 3,000\u20136,000 h. A campaign line can be far lower. This is the number that decides the case.<\/div>\r\n      <\/div>\r\n      <div class=\"fld\">\r\n        <label for=\"capexKw\">Installed cost per kW of heat <b id=\"capexKwV\">450<\/b><\/label>\r\n        <input type=\"range\" id=\"capexKw\" min=\"150\" max=\"1200\" step=\"10\" value=\"450\">\r\n        <div class=\"hint\">Complete system: unit, buffer, hydraulics and heat exchangers, controls and installation. Ex-rated zones, clean-steam exchangers and solvent-compatible materials push this up.<\/div>\r\n      <\/div>\r\n    <\/div>\r\n    <div class=\"calc-out\">\r\n      <div class=\"res hero\">\r\n        <span class=\"k\">Ten-year cost, heat pump vs boiler<\/span>\r\n        <span class=\"v\" id=\"resTco\">\u2014<\/span>\r\n      <\/div>\r\n      <div class=\"res\"><span class=\"k\">Boiler \u2014 cost per kWh of heat<\/span><span class=\"v\" id=\"resBoiler\">\u2014<\/span><\/div>\r\n      <div class=\"res\"><span class=\"k\">Heat pump \u2014 cost per kWh of heat<\/span><span class=\"v\" id=\"resHp\">\u2014<\/span><\/div>\r\n      <div class=\"res\"><span class=\"k\">Break-even COP at your prices<\/span><span class=\"v\" id=\"resBreakeven\">\u2014<\/span><\/div>\r\n      <div class=\"res\"><span class=\"k\">Annual heat delivered<\/span><span class=\"v\" id=\"resHeat\">\u2014<\/span><\/div>\r\n      <div class=\"res\"><span class=\"k\">Annual energy-cost saving<\/span><span class=\"v\" id=\"resSaving\">\u2014<\/span><\/div>\r\n      <div class=\"res\"><span class=\"k\">Simple payback on installed cost<\/span><span class=\"v\" id=\"resPayback\">\u2014<\/span><\/div>\r\n      <div class=\"bars\">\r\n        <div class=\"bar-row\">\r\n          <div class=\"bar-lab\"><span>Boiler \u00b7 10 years of energy<\/span><b id=\"barBoilerV\">\u2014<\/b><\/div>\r\n          <div class=\"bar-track\"><div class=\"bar-fill b-boiler\" id=\"barBoiler\" style=\"width:0%\"><\/div><\/div>\r\n        <\/div>\r\n        <div class=\"bar-row\">\r\n          <div class=\"bar-lab\"><span>Heat pump \u00b7 10 years incl. capital<\/span><b id=\"barHpV\">\u2014<\/b><\/div>\r\n          <div class=\"bar-track\"><div class=\"bar-fill b-hp\" id=\"barHp\" style=\"width:0%\"><\/div><\/div>\r\n        <\/div>\r\n      <\/div>\r\n      <div class=\"verdict\" id=\"tcoVerdict\">\u2014<\/div>\r\n      <p class=\"calc-foot\">All monetary outputs are in whatever currency you enter. This is a screening estimate, not a quotation \u2014 the exclusions are listed directly below.<\/p>\r\n    <\/div>\r\n  <\/div>\r\n<\/section>\r\n\r\n\r\n\r\n<div class=\"note deep\">\r\n  <b class=\"lbl\">What this TCO includes \u2014 and what it deliberately leaves out<\/b>\r\n  <p style=\"margin:0\"><strong>Included:<\/strong> installed system cost and ten years of energy cost for both options at constant prices. <strong>Excluded, and all of it favours the heat pump:<\/strong> avoided boiler servicing, fuel delivery and storage, NOx permits, flue-gas treatment, carbon cost, and any industrial electrification grant or tax credit. <strong>Excluded, and this works against it:<\/strong> electrical supply upgrades, Ex-rated equipment in zoned areas, clean-steam heat exchangers and re-validation work, pipework reroutes, and downtime during tie-in. The three formulas are the same ones used on our textile, food, new-energy and agriculture pages: <span style=\"font-family:ui-monospace,monospace\">boiler heat cost = fuel \u00f7 efficiency<\/span>, <span style=\"font-family:ui-monospace,monospace\">heat pump heat cost = electricity \u00f7 COP<\/span>, <span style=\"font-family:ui-monospace,monospace\">break-even COP = electricity \u00f7 boiler heat cost<\/span>.<\/p>\r\n<\/div>\r\n\r\n<h2 id=\"limits\">Where a heat pump stops \u2014 and what to do instead<\/h2>\r\n  <p>An application page without limits is a brochure. These are the five boundaries we hit most often in chemical and pharmaceutical projects, stated before you ask.<\/p>\r\n\r\n  <div class=\"tbl-wrap\">\r\n    <table>\r\n      <caption>The honest boundaries. None of these is a product weakness; they are thermodynamic, regulatory or metallurgical facts.<\/caption>\r\n      <thead><tr><th>Boundary<\/th><th>Why<\/th><th>Correct solution<\/th><\/tr><\/thead>\r\n      <tbody>\r\n        <tr><td><strong>Reactor jackets above 180\u2013200 \u00b0C<\/strong><\/td><td>High-temperature synthesis and cracking; cascade COP collapses and refrigerant choice narrows sharply<\/td><td>Hybrid: the heat pump preheats feed or jacket water, a fired heater supplies the top temperature<\/td><\/tr>\r\n        <tr><td><strong>Validated autoclaves and clean steam at 121 \/ 134 \u00b0C<\/strong><\/td><td>A pressure vessel with IQ\/OQ\/PQ records, steam-quality limits and air-removal validation; re-qualification is expensive<\/td><td>Keep the validated clean-steam generator; the heat pump preheats its feed and carries the utility loop<\/td><\/tr>\r\n        <tr><td><strong>Direct-fired furnaces and cracked gas above 400 \u00b0C<\/strong><\/td><td>No refrigerant cycle reaches this band; the equipment is a metallurgy problem<\/td><td>Other electrification routes for the furnace; the heat pump recovers lower-grade heat around it<\/td><\/tr>\r\n        <tr><td><strong>ATEX \/ solvent Zone 1 areas<\/strong><\/td><td>Electrical classification, refrigerant charge limits and ignition sources all have to be engineered<\/td><td>Ex-rated components, low-charge natural refrigerant where practical, indirect loop sited outside the zone<\/td><\/tr>\r\n        <tr><td><strong>Fouling, polymerising or tar-laden streams<\/strong><\/td><td>Evaporator and exchanger surfaces foul fast; downtime eats the saving<\/td><td>Indirect secondary loop, washable exchangers, or a cleaner waste-heat source<\/td><\/tr>\r\n      <\/tbody>\r\n    <\/table>\r\n  <\/div>\r\n\r\n  <h2>Standards and compliance<\/h2>\r\n  <p>Depending on where the machine lands \u2014 a solvent area, a utility room or a clean utility skid \u2014 a different set of rules applies. These are the ones that come up in project reviews.<\/p>\r\n  <div class=\"cards c2\">\r\n    <div class=\"card\">\r\n      <h4>Process and site safety<\/h4>\r\n      <p><strong>ATEX 2014\/34\/EU<\/strong> and <strong>IECEx<\/strong> for solvent and explosive atmospheres; <strong>PED 2014\/68\/EU<\/strong> and <strong>ASME VIII<\/strong> for pressure equipment; <strong>ASME B31.3<\/strong> process piping; <strong>F-Gas 517\/2014<\/strong> and the Kigali low-GWP refrigerant phase-down; functional safety and SIL where the heat pump is tied into the plant safety system.<\/p>\r\n    <\/div>\r\n    <div class=\"card\">\r\n      <h4>Pharma and clean utilities<\/h4>\r\n      <p><strong>EU GMP Annex 1<\/strong> and cGMP; <strong>FDA 21 CFR Parts 210\/211<\/strong> and <strong>Part 11<\/strong> data integrity; <strong>ISO 17665<\/strong> moist-heat sterilisation and <strong>EN 285<\/strong> steam sterilizers; <strong>ASME BPE<\/strong> hygienic design and double tube-sheet exchangers. The clean side is re-qualified only if its boundary changes \u2014 the heat pump is deliberately outside it.<\/p>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <h2>What we need to size your system<\/h2>\r\n  <p>No site visit is needed for a first-pass answer. Five pieces of information get you an indicative design, a COP range and a payback estimate.<\/p>\r\n  <ol class=\"steps\">\r\n    <li><h4>Source and sink temperatures<\/h4><p>Reboiler and condenser of each column, dryer inlet and exhaust, reactor cooling-water supply and return, CIP and WFI loop temperatures. Give us the pair, not just the peak.<\/p><\/li>\r\n    <li><h4>Load and hours<\/h4><p>Peak and average kW, the campaign calendar, batch duration and how many hours a year each loop is live. Batch plants live or die by this line.<\/p><\/li>\r\n    <li><h4>Heat source quality<\/h4><p>Flow and temperature of cooling water, condensate, hot effluent or condenser air \u2014 plus fouling, solvent content and corrosion risk.<\/p><\/li>\r\n    <li><h4>Current cost of heat<\/h4><p>Utility steam tariff or fuel price, boiler efficiency, electricity tariff including demand charges, and any carbon price or gas cost already in the budget.<\/p><\/li>\r\n    <li><h4>Site constraints<\/h4><p>Ex-rated zones, clean-utility boundaries, space for buffer tanks and heat exchangers, condensate return, and what re-validation would cost if the clean side were touched.<\/p><\/li>\r\n  <\/ol>\r\n\r\n  <div class=\"formula\">\r\n    <b>Recoverable heat from a water stream<\/b><br>\r\n    Q (kW) \u2248 1.163 \u00d7 V (m\u00b3\/h) \u00d7 \u0394T (K)<br>\r\n    <span style=\"color:#CDB4B7\">Example: 100 m\u00b3\/h of reactor cooling water cooled from 55 \u00b0C to 35 \u00b0C \u2192 1.163 \u00d7 100 \u00d7 20 \u2248 2,326 kW of heat already leaving the site \u2014 before condensate or hot effluent is counted. That is why the source survey comes before the machine selection.<\/span>\r\n  <\/div>\r\n\r\n  <div class=\"note\">\r\n    <b class=\"lbl\">What this page does not claim<\/b>\r\n    COP and payback figures here are indicative ranges drawn from published system data and our own project experience \u2014 not guaranteed performance. The BASF and AstraZeneca installations cited above are references to what the technology has done, not comparable performance claims for your site. Process temperatures vary by product, solvent and validated procedure; confirm them with your process engineer and QA before sizing. We will put a specific number against your specific numbers, in writing, before you commit to anything.\r\n  <\/div>\r\n\r\n<h2>FAQ<\/h2>\r\n  <div class=\"faq\">\r\n    <details>\r\n      <summary>Can a heat pump make process steam for a chemical plant?<\/summary>\r\n      <div class=\"ans\">Yes \u2014 up to about 150 \u00b0C and roughly 5 bar with current commercial cascade machines. Published chemical installations include a 50 MW thermal unit at BASF's Ludwigshafen site supplying steam for formic-acid production, and a pharmaceutical site in Sweden using a 500 kW heat pump to deliver steam at 10 bar. Above 150 \u00b0C the sector is still pre-commercial; the honest answer there is a hybrid, with the heat pump carrying the base load and a fired heater supplying the peak. Our <a class=\"plink\" href=\"https:\/\/hetapro.com\/products\/ht-w2s-150c-steam-heat-pump\/\" target=\"_blank\" rel=\"noopener\">HT-W2S<\/a> and <a class=\"plink\" href=\"https:\/\/hetapro.com\/products\/ht-a2s-150c-steam-heat-pump\/\" target=\"_blank\" rel=\"noopener\">HT-A2S<\/a> sit at the top of that commercial range.<\/div>\r\n    <\/details>\r\n    <details>\r\n      <summary>What about the 121 \u00b0C autoclave and GMP clean steam?<\/summary>\r\n      <div class=\"ans\">A sterilising autoclave at 121 \u00b0C for 20 minutes or 134 \u00b0C for 5 minutes is a validated pressure vessel with defined steam quality, air removal and IQ\/OQ\/PQ records. It should stay on its clean-steam generator. The heat pump works upstream: preheating boiler feedwater, carrying the utility hot-water loop and feeding the generator's primary side through a double tube-sheet exchanger. Refrigerant never enters the clean side, which is precisely why the project remains approvable.<\/div>\r\n    <\/details>\r\n    <details>\r\n      <summary>Where does the waste heat come from on a batch plant?<\/summary>\r\n      <div class=\"ans\">Distillation and vacuum condensers at 35\u201360 \u00b0C, reactor cooling water at 40\u201390 \u00b0C, hot condensate and effluent at 50\u201395 \u00b0C, and chiller condensers at 30\u201340 \u00b0C. Batch timing is the difficulty, not the temperature: a buffer tank lets a ninety-minute exotherm feed a machine that runs all day. Size the buffer first. Without one, a site that is physically a good fit can look like a poor fit on paper.<\/div>\r\n    <\/details>\r\n    <details>\r\n      <summary>Is it safe in a solvent or ATEX area?<\/summary>\r\n      <div class=\"ans\">It can be, but the zone classification comes first. Specify Ex-rated electrical components, a low-charge natural refrigerant where practical, and an indirect water or glycol loop that keeps the machine outside Zone 1. Materials of construction and refrigerant choice are then reviewed against the solvent and the process pressure boundary. We will not quote a standard skid into a zoned area without that review.<\/div>\r\n    <\/details>\r\n    <details>\r\n      <summary>How does a heat pump compare with mechanical vapour recompression?<\/summary>\r\n      <div class=\"ans\">They are usually complementary. MVR compresses the vapour boiled off in one evaporation effect; a heat pump lifts heat from a separate low-grade source to a higher-temperature sink. In a typical study the heat pump preheats the feed, MVR handles the evaporation effect and a boiler keeps a small trim duty. Ask for both options priced in the same report \u2014 comparing them on COP alone misses the engineering difference.<\/div>\r\n    <\/details>\r\n    <details>\r\n      <summary>What COP should I assume for a distillation reboiler?<\/summary>\r\n      <div class=\"ans\">It depends on the condenser and reboiler temperatures, not on nameplate figures. Lifting heat from a 40\u201360 \u00b0C condenser to a 95\u2013130 \u00b0C reboiler typically lands at 2.5\u20133.4. A vacuum column with a 35\u201355 \u00b0C condenser and an 80\u201395 \u00b0C reboiler can reach 3.4\u20133.9. Use the selector on this page for a first pass, then replace the figure with a guaranteed value at your own duty point.<\/div>\r\n    <\/details>\r\n  <\/div>\r\n\r\n  <div class=\"cta\">\r\n    <h2>Send us three numbers. Get a real answer.<\/h2>\r\n    <p>Your reboiler and source temperatures, the hours they actually run, and what you pay for heat today. That is enough for an indicative COP, a recommended series and a payback range \u2014 with the GMP and ATEX boundaries stated, not hidden.<\/p>\r\n    <p style=\"margin-top:22px\">\r\n      <a class=\"btn btn-p\" href=\"https:\/\/hetapro.com\/contact\/\">Talk to our engineers<\/a>\r\n      <a class=\"btn btn-outline\" style=\"margin-left:8px\" href=\"#finder\">Back to the process index<\/a>\r\n    <\/p>\r\n  <\/div>\r\n\r\n  <h2>Sources and basis<\/h2>\r\n  <ul class=\"src\">\r\n    <li>High-temperature heat pump potential in the 100\u2013150 \u00b0C supply range for the food, paper and chemical\/pharma industries \u2014 specifically drying, pasteurising, sterilising, evaporation and distillation: NetZeroCities, <em>High Temperature Heat Pumps<\/em> resource (netzerocities.app\/resource-1458).<\/li>\r\n    <li>Steam use below 200 \u00b0C across the chemical sector; commercial traction at 150\u2013185 \u00b0C and pre-commercial status above 150 \u00b0C: PatSnap, <em>Industrial Heat Pump High Temperature Process Technology Landscape 2026<\/em>.<\/li>\r\n    <li>Industrial heat shares of roughly 10 % below 100 \u00b0C and 26 % between 100 and 200 \u00b0C in Europe: German energy-agency studies as cited by <em>Beyond Tomorrow<\/em>, 2026.<\/li>\r\n    <li>BASF Ludwigshafen 50 MW thermal heat pump, up to 500,000 tonnes of CO\u2082-free steam per year for formic acid, driven by steam-cracker waste heat through eleven compressors: <em>Beyond Tomorrow<\/em>, 2026.<\/li>\r\n    <li>AstraZeneca Sweden \/ Olvondo Stirling-cycle heat pump producing 500 kW of steam at 10 bar: PatSnap landscape, 2026.<\/li>\r\n    <li>Moist-heat sterilisation at 121 \u00b0C for 20 minutes or 134 \u00b0C for 5 minutes, saturated steam quality and validation to ISO 17665 \/ EN 285 \/ cGMP: pharmaceutical sterilisation references, 2024\u20132026.<\/li>\r\n    <li>Wet-granulation temperature control at 40\u201360 \u00b0C and clean hot-air drying at 60\u201380 \u00b0C: published pharmaceutical process guidance, 2025.<\/li>\r\n    <li>Heat-pump dryer specific moisture extraction rate of 1\u20132 kg\/kWh: published heat-pump drying process data.<\/li>\r\n  <\/ul>\r\n\r\n<\/main>\r\n\r\n<footer>\r\n  <div class=\"wrap\">\r\n    <p><strong style=\"color:var(--ink)\">HETAPRO<\/strong> \u2014 Industrial high-temperature heat pumps: hot water to 95\u2013135 \u00b0C, steam to 150 \u00b0C, drying air 30\u201385 \u00b0C.<\/p>\r\n    <p>\r\n      <a href=\"https:\/\/hetapro.com\/industrial_high_temperature_heat_pumps_solution_for_textiles\/\">Textile solutions<\/a> \u00b7\r\n      <a href=\"https:\/\/hetapro.com\/industrial-high-temperature-heat-pumps-solutions-for-food-and-beverage-industry\/\">Food &amp; beverage solutions<\/a> \u00b7\r\n      <a href=\"https:\/\/hetapro.com\/new-energy-electronics-heat-pump-solutions\/\">New energy &amp; electronics<\/a> \u00b7\r\n      <a href=\"https:\/\/hetapro.com\/agriculture-food-heat-pump-solutions\/\">Agriculture &amp; food<\/a> \u00b7\r\n      <a href=\"https:\/\/hetapro.com\/contact\/\">Contact<\/a>\r\n    <\/p>\r\n    <p>\u00a9 2026 HETAPRO. Specifications subject to change. Figures on this page are engineering guidance, not contractual performance data.<\/p>\r\n  <\/div>\r\n<\/footer>\r\n\r\n<script>\r\n(function(){\r\n  var chips = Array.prototype.slice.call(document.querySelectorAll('.chip'));\r\n  var items = Array.prototype.slice.call(document.querySelectorAll('.pfind-item'));\r\n  var sum = document.getElementById('pfSum');\r\n  var active = 'all';\r\n\r\n  function apply(){\r\n    var shown = 0;\r\n    items.forEach(function(el){\r\n      var ok = (active === 'all') || (el.getAttribute('data-band') === active);\r\n      if (ok) { el.removeAttribute('hidden'); shown++; }\r\n      else { el.setAttribute('hidden',''); }\r\n    });\r\n    chips.forEach(function(c){\r\n      c.setAttribute('aria-pressed', String(c.getAttribute('data-band') === active));\r\n    });\r\n    if (sum) {\r\n      sum.textContent = (active === 'all')\r\n        ? 'Showing ' + shown + ' unit operations across separation, drying, clean utilities and heat recovery.'\r\n        : 'Showing ' + shown + ' unit operation' + (shown === 1 ? '' : 's') + ' in this temperature band.';\r\n    }\r\n  }\r\n\r\n  chips.forEach(function(c){\r\n    c.addEventListener('click', function(){\r\n      active = c.getAttribute('data-band');\r\n      apply();\r\n    });\r\n  });\r\n  apply();\r\n})();\r\n<\/script>\r\n<script>\r\n(function(){\r\n  \/* ---------- the six series ---------- *\/\r\n  var SERIES = [\r\n    {\r\n      lo:30, hi:60, temp:\"30 \/ 60 \u00b0C\", name:\"Cooling-water heat & clean utilities\",\r\n      process:\"Reactor cooling, column condensers, WFI preheat, cleanroom HVAC\",\r\n      desc:\"Chemical sites reject enormous amounts of low-grade heat: reactor cooling water at 40\u201390 \u00b0C, vacuum condensers at 35\u201355 \u00b0C, chiller condensers at 30\u201340 \u00b0C and WFI loops needing 25\u201345 \u00b0C preheat. At this lift the COP is the highest in the range and the equipment is close to a catalogue item. Start here \u2014 it is where the heat already exists.\",\r\n      cop:\"4.6 \u2013 5.2\", duty:\"Hot water \/ hot air\", src:\"Cooling water, condenser, effluent\", boiler:\"No\"\r\n    },\r\n    {\r\n      lo:61, hi:80, temp:\"60 \/ 80 \u00b0C\", name:\"Drying & clean hot water\",\r\n      process:\"Wet granules, tablets, API drying, CIP and wash water\",\r\n      desc:\"Pharmaceutical drying is deliberately gentle: wet granules 60\u201380 \u00b0C, coated tablets lower, API often below 90 \u00b0C to protect actives. The exhaust is warm and moist, so a dehumidifying heat pump recovers its latent heat and shortens the cycle. CIP wash water and WFI preheat are steady water loops that can share the same machine through a buffer tank.\",\r\n      cop:\"3.9 \u2013 4.6\", duty:\"Dehumidified hot air \/ hot water\", src:\"Dryer exhaust, cooling water\", boiler:\"No\"\r\n    },\r\n    {\r\n      lo:81, hi:95, temp:\"80 \/ 95 \u00b0C\", name:\"Vacuum separation & extraction\",\r\n      process:\"Vacuum reboilers, multi-effect evaporators, extraction, hot WFI\",\r\n      desc:\"The natural first target on a chemical site. A vacuum column reboiler at 80\u201395 \u00b0C can be fed from its own 35\u201355 \u00b0C condenser; evaporator first effects and solvent extraction sit in the same band. Hot WFI loops and liquid-pharma pasteurisation are clean, steady water duties. COP stays above 3.4 because source and sink are close.\",\r\n      cop:\"3.4 \u2013 3.9\", duty:\"Pressurised hot water\", src:\"Column condenser, hot condensate\", boiler:\"Trim advised\"\r\n    },\r\n    {\r\n      lo:96, hi:110, temp:\"95 \/ 110 \u00b0C\", name:\"Solvent recovery & reaction heat\",\r\n      process:\"Solvent columns, reaction jackets, crystallisers, clean hot water\",\r\n      desc:\"Atmospheric solvent-recovery columns, reaction jackets built around hot water, and crystalliser heating all sit here. Waste heat is warmer \u2014 50\u201395 \u00b0C condensate and reactor cooling water \u2014 which keeps the lift manageable. Refrigerant choice and materials of construction matter as soon as solvent is present; specify the exchanger side accordingly.\",\r\n      cop:\"3.0 \u2013 3.4\", duty:\"Hot water \/ low-pressure steam\", src:\"Hot condensate, reactor jacket water\", boiler:\"Trim advised\"\r\n    },\r\n    {\r\n      lo:111, hi:130, temp:\"110 \/ 130 \u00b0C\", name:\"Low-pressure process steam\",\r\n      process:\"Reactor kettles, evaporators, reboilers, condensate return\",\r\n      desc:\"Where the plant was built around steam, 110\u2013130 \u00b0C covers most reactors, kettles and reboilers. COP falls to 2.5\u20133.0, so the case needs long hours, a real condensate return and a close source. One hard boundary carries over from our food pages: a 121 \u00b0C autoclave is a validated pressure vessel and keeps its clean-steam generator.\",\r\n      cop:\"2.5 \u2013 3.0\", duty:\"Steam 110\u2013130 \u00b0C\", src:\"Condensate, flash steam, flue gas\", boiler:\"Retained for clean steam\"\r\n    },\r\n    {\r\n      lo:131, hi:150, temp:\"130 \/ 150 \u00b0C\", name:\"High-temperature steam & MVR\",\r\n      process:\"High-rate reboilers, multi-effect evaporation, hybrid steam systems\",\r\n      desc:\"The top of our range and the edge of current commercial cascade machines. Published chemical plants reach this band with large multi-compressor systems; beyond 150 \u00b0C the sector is still pre-commercial. At this lift COP is 2.0\u20132.5 and the honest answer is often a hybrid \u2014 heat pump for the base load, boiler for the peak. MVR may beat both for a single-effect evaporator.\",\r\n      cop:\"2.0 \u2013 2.5\", duty:\"Saturated steam\", src:\"High-grade waste heat \/ flue gas\", boiler:\"Retained \/ hybrid\"\r\n    }\r\n  ];\r\n\r\n  \/* indicative COP by delivery temperature, consistent with the figures quoted on this page *\/\r\n  var CURVE = [\r\n    {t:30,c:5.2},{t:60,c:4.5},{t:80,c:3.9},{t:95,c:3.4},\r\n    {t:110,c:3.0},{t:130,c:2.5},{t:150,c:2.0}\r\n  ];\r\n\r\n  var slider   = document.getElementById('tempSlider');\r\n  var tVal     = document.getElementById('tVal');\r\n  var tSeries  = document.getElementById('tSeries');\r\n  var tProcess = document.getElementById('tProcess');\r\n  var tDesc    = document.getElementById('tDesc');\r\n  var tCop     = document.getElementById('tCop');\r\n  var tDuty    = document.getElementById('tDuty');\r\n  var tSrc     = document.getElementById('tSrc');\r\n  var tBoiler  = document.getElementById('tBoiler');\r\n  var cardsBox = document.getElementById('tCards');\r\n\r\n  function findSeries(t){\r\n    for(var i=0;i<SERIES.length;i++){\r\n      if(t >= SERIES[i].lo && t <= SERIES[i].hi) return SERIES[i];\r\n    }\r\n    return SERIES[SERIES.length-1];\r\n  }\r\n\r\n  function copAt(t){\r\n    if(t <= CURVE[0].t) return CURVE[0].c;\r\n    if(t >= CURVE[CURVE.length-1].t) return CURVE[CURVE.length-1].c;\r\n    for(var i=1;i<CURVE.length;i++){\r\n      if(t <= CURVE[i].t){\r\n        var a=CURVE[i-1], b=CURVE[i];\r\n        return a.c + (t-a.t)\/(b.t-a.t)*(b.c-a.c);\r\n      }\r\n    }\r\n    return CURVE[CURVE.length-1].c;\r\n  }\r\n\r\n  \/* ---------- clickable series cards ---------- *\/\r\n  var cardEls = [];\r\n  SERIES.forEach(function(s, idx){\r\n    var el = document.createElement('div');\r\n    el.className = 'series';\r\n    el.setAttribute('role','button');\r\n    el.setAttribute('tabindex','0');\r\n    el.innerHTML =\r\n      '<div class=\"sn\">0'+(idx+1)+'<\/div>'+\r\n      '<div class=\"st\">'+s.temp+'<\/div>'+\r\n      '<div class=\"sl\">'+s.name+'<\/div>'+\r\n      '<p>'+s.process+'<\/p>';\r\n    function go(){\r\n      slider.value = s.lo + Math.round((s.hi - s.lo)\/2);\r\n      update();\r\n      el.scrollIntoView({behavior:'smooth', block:'nearest'});\r\n    }\r\n    el.addEventListener('click', go);\r\n    el.addEventListener('keydown', function(e){\r\n      if(e.key==='Enter' || e.key===' '){ e.preventDefault(); go(); }\r\n    });\r\n    cardsBox.appendChild(el);\r\n    cardEls.push(el);\r\n  });\r\n\r\n  \/* ---------- TCO inputs ---------- *\/\r\n  var fuelEl = document.getElementById('fuelPrice'),\r\n      elecEl = document.getElementById('elecPrice'),\r\n      effEl  = document.getElementById('boilerEff'),\r\n      copEl  = document.getElementById('copSel'),\r\n      loadEl = document.getElementById('loadKw'),\r\n      hrsEl  = document.getElementById('runHours'),\r\n      capEl  = document.getElementById('capexKw');\r\n\r\n  function money(v){\r\n    if(v >= 1e6) return (v\/1e6).toFixed(2) + ' M';\r\n    if(v >= 1e3) return (v\/1e3).toFixed(0) + ' k';\r\n    return v.toFixed(0);\r\n  }\r\n\r\n  function update(){\r\n    var t = parseInt(slider.value, 10);\r\n    var s = findSeries(t);\r\n\r\n    tVal.innerHTML = t + '<small>\u00b0C<\/small>';\r\n    tSeries.textContent = s.name;\r\n    tProcess.textContent = s.process + ' \u2014 ' + s.temp;\r\n    tDesc.textContent = s.desc;\r\n    tCop.textContent = s.cop;\r\n    tDuty.textContent = s.duty;\r\n    tSrc.textContent = s.src;\r\n    tBoiler.textContent = s.boiler;\r\n\r\n    slider.setAttribute('aria-valuetext', t + ' degrees Celsius, ' + s.name);\r\n\r\n    cardEls.forEach(function(el, i){\r\n      el.classList.toggle('active', SERIES[i] === s);\r\n    });\r\n\r\n    \/* highlight the machines that serve this band *\/\r\n    var idx = SERIES.indexOf(s) + 1;\r\n    var pCards = document.querySelectorAll('#pGrid .pcard');\r\n    for (var i=0;i<pCards.length;i++){\r\n      var list = (pCards[i].getAttribute('data-series')||'').split(',');\r\n      pCards[i].classList.toggle('rec', list.indexOf(String(idx)) !== -1);\r\n    }\r\n\r\n    \/* keep the calculator's COP on the selected band *\/\r\n    var c = copAt(t);\r\n    copEl.value = c.toFixed(1);\r\n    document.getElementById('copSelV').textContent = c.toFixed(1);\r\n    calc();\r\n  }\r\n\r\n  \/* ---------- TCO model ---------- *\/\r\n  function calc(){\r\n    var fuel  = parseFloat(fuelEl.value),\r\n        elec  = parseFloat(elecEl.value),\r\n        eff   = parseFloat(effEl.value)\/100,\r\n        cop   = parseFloat(copEl.value),\r\n        load  = parseFloat(loadEl.value),\r\n        hrs   = parseFloat(hrsEl.value),\r\n        capKw = parseFloat(capEl.value);\r\n\r\n    document.getElementById('fuelPriceV').textContent  = fuel.toFixed(3);\r\n    document.getElementById('elecPriceV').textContent  = elec.toFixed(3);\r\n    document.getElementById('boilerEffV').textContent  = Math.round(eff*100) + ' %';\r\n    document.getElementById('copSelV').textContent     = cop.toFixed(1);\r\n    document.getElementById('loadKwV').textContent     = load.toLocaleString() + ' kW';\r\n    document.getElementById('runHoursV').textContent   = hrs.toLocaleString() + ' h';\r\n    document.getElementById('capexKwV').textContent    = capKw.toFixed(0);\r\n\r\n    var boilerCost = fuel\/eff;              \/* currency per kWh of heat *\/\r\n    var hpCost     = elec\/cop;\r\n    var be         = elec\/boilerCost;       \/* break-even COP *\/\r\n    var annualKwh  = load*hrs;              \/* kWh of heat per year *\/\r\n    var annualSave = (boilerCost - hpCost) * annualKwh;\r\n    var capex      = load*capKw;\r\n    var boiler10   = boilerCost * annualKwh * 10;\r\n    var hp10       = capex + hpCost * annualKwh * 10;\r\n    var diff       = (hp10 - boiler10) \/ boiler10 * 100;\r\n    var payback    = annualSave > 0 ? capex\/annualSave : Infinity;\r\n\r\n    document.getElementById('resBoiler').textContent    = boilerCost.toFixed(3) + ' \/ kWh';\r\n    document.getElementById('resHp').textContent        = hpCost.toFixed(3) + ' \/ kWh';\r\n    document.getElementById('resBreakeven').textContent = be.toFixed(2);\r\n    document.getElementById('resHeat').textContent      = (annualKwh\/1000).toLocaleString(undefined,{maximumFractionDigits:0}) + ' MWh';\r\n    document.getElementById('resSaving').textContent    = (annualSave>=0?'':'\u2212') + money(Math.abs(annualSave)) + ' \/ yr';\r\n    var pbText = (!isFinite(payback) || payback > 99) ? 'beyond 99 years' : payback.toFixed(1) + ' years';\r\n    document.getElementById('resPayback').textContent   = pbText;\r\n\r\n    var tv = document.getElementById('resTco');\r\n    tv.textContent = (diff<=0?'\u2212':'+') + (Math.abs(diff) > 999 ? '999+' : Math.abs(diff).toFixed(0)) + '%';\r\n    tv.className = 'v ' + (diff<=0 ? 'up' : 'dn');\r\n\r\n    \/* ten-year bars *\/\r\n    var max = Math.max(boiler10, hp10);\r\n    document.getElementById('barBoiler').style.width = (boiler10\/max*100).toFixed(1) + '%';\r\n    document.getElementById('barHp').style.width     = (hp10\/max*100).toFixed(1) + '%';\r\n    document.getElementById('barBoilerV').textContent = money(boiler10);\r\n    document.getElementById('barHpV').textContent     = money(hp10);\r\n\r\n    var v = document.getElementById('tcoVerdict');\r\n    if(hpCost >= boilerCost){\r\n      v.className = 'verdict no';\r\n      v.innerHTML = '<b>Not economic on energy cost.<\/b> At COP '+cop.toFixed(1)+' the heat pump costs '+\r\n        Math.abs((hpCost\/boilerCost-1)*100).toFixed(0)+'% more per kWh of heat than the boiler, and you would need COP '+\r\n        be.toFixed(2)+' to break even. Three levers, in order of effect: recover waste heat so the lift shrinks, lower the delivery temperature where the process allows, or improve boiler efficiency \u2014 a boiler running at 70% makes the heat pump look far better than one at 92%.';\r\n    } else if(payback <= 3){\r\n      var need = capex \/ ((boilerCost-hpCost) * load * 5);\r\n      v.className = 'verdict ok';\r\n      v.innerHTML = '<b>Clear case, capital included.<\/b> Ten-year cost is '+Math.abs(diff).toFixed(0)+\r\n        '% lower and payback is '+payback.toFixed(1)+' years at '+hrs.toLocaleString()+' hours a year. '+\r\n        (need <= 8760\r\n          ? 'A five-year payback holds as long as you run at least '+Math.round(need).toLocaleString()+' hours a year \u2014 inside a normal seasonal year.'\r\n          : 'Note that a five-year payback would need '+Math.round(need).toLocaleString()+' hours a year, which is more than a continuous year: at this capital cost the case depends on running closer to 24\/7.');\r\n    } else if(payback <= 6){\r\n      v.className = 'verdict mid';\r\n      v.innerHTML = '<b>Workable, but the capital dominates.<\/b> Payback is '+payback.toFixed(1)+\r\n        ' years, which is a normal industrial project rather than a standout one. It becomes comfortable below five years with a grant or tax credit, a carbon price, a longer operating year, or a staged scope where the first machine serves only the highest-hour loop rather than the whole plant.';\r\n    } else {\r\n      v.className = 'verdict no';\r\n      v.innerHTML = '<b>Not on these numbers.<\/b> Payback is '+pbText+\r\n        '. Before abandoning it, check three things: are the operating hours real or nameplate, is the load an average or a peak, and does the capital include scope you do not need yet? A partial system serving one long, steady loop often pays back twice as fast as a whole-site design.';\r\n    }\r\n  }\r\n\r\n  slider.addEventListener('input', update);\r\n  [fuelEl, elecEl, effEl, copEl, loadEl, hrsEl, capEl].forEach(function(el){\r\n    el.addEventListener('input', calc);\r\n  });\r\n\r\n  update();\r\n})();\r\n<\/script>\r\n\r\n\r\n<script>\r\n\/* \u9996\u5c4f\u4e0b\u65b9\u7ae0\u8282 tab\uff1a\u6eda\u52a8\u9ad8\u4eae\u5f53\u524d\u7ae0\u8282\uff0c\u70b9\u51fb\u5373\u65f6\u6fc0\u6d3b\uff1b\u79fb\u52a8\u7aef\u81ea\u52a8\u5c06\u6fc0\u6d3b\u9879\u6eda\u5165\u89c6\u91ce *\/\r\n(function () {\r\n  var bar = document.querySelector('.tabbar');\r\n  var strip = document.querySelector('.tabs');\r\n  var tabs = [].slice.call(document.querySelectorAll('.tabbar .tab:not(.tab-cta)'));\r\n  if (!bar || !strip || !tabs.length) return;\r\n\r\n  \/* \u907f\u8ba9\u7ad9\u70b9\u56fa\u5b9a\u5934\u90e8\uff1atab \u6761\u505c\u9760\u5728 WordPress\/Elementor \u5934\u90e8\u4e0b\u65b9 *\/\r\n  var siteHeader = document.querySelector('.elementor-location-header, header.elementor-location-header, .site-header, #site-header');\r\n  function syncHeaderOffset() {\r\n    var h = 0;\r\n    if (siteHeader) {\r\n      var cs = getComputedStyle(siteHeader);\r\n      if (cs.position === 'fixed' || cs.position === 'sticky') {\r\n        var r = siteHeader.getBoundingClientRect();\r\n        if (r.height > 30 && r.height < 160) h = Math.ceil(r.bottom);\r\n      }\r\n    }\r\n    var fallback = \/^hetapro\\.com$\/.test(location.hostname) ? '72px' : '0px';\r\n    document.documentElement.style.setProperty('--site-header-h', h ? h + 'px' : fallback);\r\n  }\r\n  syncHeaderOffset();\r\n  window.addEventListener('load', syncHeaderOffset);\r\n  window.addEventListener('resize', syncHeaderOffset);\r\n\r\n  var targets = tabs.map(function (a) {\r\n    return { a: a, el: document.getElementById(a.getAttribute('href').slice(1)) };\r\n  }).filter(function (t) { return t.el; });\r\n\r\n  var lastId = null;\r\n  function activate(id) {\r\n    if (id === lastId) return;\r\n    lastId = id;\r\n    tabs.forEach(function (a) {\r\n      if (a.getAttribute('href') === '#' + id) a.setAttribute('aria-current', 'location');\r\n      else a.removeAttribute('aria-current');\r\n    });\r\n    var active = tabs.filter(function (a) { return a.getAttribute('href') === '#' + id; })[0];\r\n    if (active && strip.scrollWidth > strip.clientWidth) {\r\n      var box = active.getBoundingClientRect();\r\n      var wrapBox = strip.getBoundingClientRect();\r\n      if (box.left < wrapBox.left || box.right > wrapBox.right) {\r\n        strip.scrollTo({ left: active.offsetLeft - strip.clientWidth \/ 2 + active.offsetWidth \/ 2, behavior: 'smooth' });\r\n      }\r\n    }\r\n  }\r\n\r\n  function update() {\r\n    var line = bar.getBoundingClientRect().height + 96;\r\n    var cta = document.getElementById('cta');\r\n    if (cta && cta.getBoundingClientRect().top <= line) {\r\n      if (lastId !== null) {\r\n        lastId = null;\r\n        tabs.forEach(function (a) { a.removeAttribute('aria-current'); });\r\n      }\r\n      return;\r\n    }\r\n    var current = targets.length ? targets[0].a.getAttribute('href').slice(1) : null;\r\n    targets.forEach(function (t) {\r\n      if (t.el.getBoundingClientRect().top <= line) current = t.a.getAttribute('href').slice(1);\r\n    });\r\n    if (current) activate(current);\r\n  }\r\n  \/* scroll + IntersectionObserver + \u4f4e\u9891\u8f6e\u8be2\u4e09\u91cd\u89e6\u53d1\uff0c\u907f\u514d\u540e\u53f0\u6807\u7b7e\/\u65e0\u5934\u73af\u5883\u6f0f\u4e8b\u4ef6 *\/\r\n  window.addEventListener('scroll', update, { passive: true });\r\n  window.addEventListener('resize', update);\r\n  if ('IntersectionObserver' in window) {\r\n    var io = new IntersectionObserver(update, { rootMargin: '-70px 0px -55% 0px', threshold: 0 });\r\n    targets.forEach(function (t) { io.observe(t.el); });\r\n    var ctaEl = document.getElementById('cta');\r\n    if (ctaEl) io.observe(ctaEl);\r\n  }\r\n  tabs.forEach(function (a) {\r\n    a.addEventListener('click', function () {\r\n      lastId = null;\r\n      activate(a.getAttribute('href').slice(1));\r\n    });\r\n  });\r\n  update();\r\n  setInterval(update, 180);\r\n})();\r\n<\/script>\r\n\r\n<\/body>\r\n<\/html>\r\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Heat Pumps for Chemical &amp; Pharma | HETAPRO Applications \u00b7 Chemical &amp; Pharmaceutical \u00b7 2026 Distil it.Dry it.Keep it sterile. A chemical site moves more heat than almost anything else. A column boils at the bottom and rejects heat at the top; a reactor exotherm runs alongside a jacket that needs 120 \u00b0C; a tablet [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"Chemical and Pharma Heat Pump Solutions","_seopress_titles_desc":"Chemical and Pharma Heat Pump Solutions","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[],"footnotes":""},"class_list":["post-5537","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/hetapro.com\/es\/wp-json\/wp\/v2\/pages\/5537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hetapro.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/hetapro.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/hetapro.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hetapro.com\/es\/wp-json\/wp\/v2\/comments?post=5537"}],"version-history":[{"count":11,"href":"https:\/\/hetapro.com\/es\/wp-json\/wp\/v2\/pages\/5537\/revisions"}],"predecessor-version":[{"id":5549,"href":"https:\/\/hetapro.com\/es\/wp-json\/wp\/v2\/pages\/5537\/revisions\/5549"}],"wp:attachment":[{"href":"https:\/\/hetapro.com\/es\/wp-json\/wp\/v2\/media?parent=5537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}