{"id":5003,"date":"2025-10-23T09:18:04","date_gmt":"2025-10-23T09:18:04","guid":{"rendered":"https:\/\/hetapro.com\/?p=5003"},"modified":"2025-10-23T14:26:37","modified_gmt":"2025-10-23T14:26:37","slug":"what-hvac-technicians-must-know-about-r290-refrigerant-and-leak-detection","status":"publish","type":"post","link":"https:\/\/hetapro.com\/pt\/what-hvac-technicians-must-know-about-r290-refrigerant-and-leak-detection\/","title":{"rendered":"O que os t\u00e9cnicos de HVAC devem saber sobre o refrigerante R290 e detec\u00e7\u00e3o de vazamentos"},"content":{"rendered":"<div style=\"background-color:#f2f2f2;\" class=\"has-background wp-block-wpseopress-table-of-contents\"><h2>\u00cdndice<\/h2><nav><ul><li><a href=\"#strongintroduction-r290-for-modern-heat-pumps-strong\">Introdu\u00e7\u00e3o: R290 para bombas de calor modernas<\/a><\/li><li><a href=\"#stronghow-r290-behaves-key-safety-facts-strong\">Como o R290 se comporta \u2014 Principais informa\u00e7\u00f5es de seguran\u00e7a<\/a><\/li><li><a href=\"#strongwhy-a-hydrocarbon-gas-detector-is-essential-strong\">Por que um detector de g\u00e1s hidrocarboneto \u00e9 essencial<\/a><\/li><li><a href=\"#strongworkspace-controls-ventilation-and-fire-safety-strong\">Controles do espa\u00e7o de trabalho, ventila\u00e7\u00e3o e seguran\u00e7a contra inc\u00eandio<\/a><\/li><li><a href=\"#strongtools-recovery-equipment-and-electrical-parts-strong\">Ferramentas, equipamentos de recupera\u00e7\u00e3o e pe\u00e7as el\u00e9tricas<\/a><\/li><li><a href=\"#strongsystem-diagnostics-and-common-failure-causes-strong\">Diagn\u00f3stico do sistema e causas comuns de falhas<\/a><\/li><li><a href=\"#strongservice-workflow-step-by-step-best-practices-strong\">Fluxo de trabalho de servi\u00e7o: pr\u00e1ticas recomendadas passo a passo<\/a><\/li><li><a href=\"#strongproduct-spotlight-mr-hybrid-built-in-leak-detection-strong\">Destaque do produto: Mr. Hybrid \u2014 Detec\u00e7\u00e3o de vazamento integrada<\/a><\/li><li><a href=\"#strongproduct-option-heatix-monobloc-optional-leak-detector-strong\">Op\u00e7\u00e3o de produto: Heatix Monobloc \u2014 Detector de vazamento opcional<\/a><\/li><li><a href=\"#strongregulatory-and-practical-benefits-strong\">Benef\u00edcios regulat\u00f3rios e pr\u00e1ticos<\/a><\/li><li><a href=\"#strongconclusion-practical-steps-for-safe-r290-service-strong\">Conclus\u00e3o: Etapas pr\u00e1ticas para um servi\u00e7o seguro de R290<\/a><\/li><li><a href=\"#frequently-asked-questions-faq\">Perguntas Frequentes (FAQ)<\/a><\/li><\/ul><\/nav><\/div>\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"683\" height=\"1024\" src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/r290-refrigerant-leak-detector-683x1024.png\" alt=\"r290 refrigerant leak detector\" class=\"wp-image-5008\" srcset=\"https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/r290-refrigerant-leak-detector-683x1024.png 683w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/r290-refrigerant-leak-detector-200x300.png 200w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/r290-refrigerant-leak-detector-768x1152.png 768w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/r290-refrigerant-leak-detector-8x12.png 8w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/r290-refrigerant-leak-detector-600x900.png 600w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/r290-refrigerant-leak-detector.png 1024w\" sizes=\"(max-width: 683px) 100vw, 683px\" \/><figcaption class=\"wp-element-caption\">detector de vazamento de refrigerante r290<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongintroduction-r290-for-modern-heat-pumps-strong\"><strong>Introdu\u00e7\u00e3o: R290 para bombas de calor modernas<\/strong><\/h2>\n\n\n\n<p>R290 (propano) proporciona excelente efici\u00eancia termodin\u00e2mica.<br>Por isso, instaladores e revendedores cada vez mais o especificam para bombas de calor compactas.<br>No entanto, o R290 \u00e9 inflam\u00e1vel, por isso os t\u00e9cnicos devem respeitar as normas de seguran\u00e7a.<br>Dessa forma, a detec\u00e7\u00e3o de vazamentos e os procedimentos adequados tornam o R290 pr\u00e1tico e seguro.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"stronghow-r290-behaves-key-safety-facts-strong\"><strong>Como o R290 se comporta \u2014 Principais informa\u00e7\u00f5es de seguran\u00e7a<\/strong><\/h2>\n\n\n\n<p>O R290 tem um limite de inflamabilidade baixo de cerca de 2,1%.<br>Al\u00e9m disso, seu limite superior de inflamabilidade \u00e9 pr\u00f3ximo de 9,5%.<br>Portanto, o g\u00e1s deve estar entre essas porcentagens para inflamar.<br>Como o R290 \u00e9 mais pesado que o ar, ele se acumula em pontos baixos.<br>Consequentemente, os espa\u00e7os dos arm\u00e1rios e do ch\u00e3o podem concentrar o g\u00e1s vazado.<br>Portanto, sempre ventile e monitore primeiro as \u00e1reas baixas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongwhy-a-hydrocarbon-gas-detector-is-essential-strong\"><strong>Por que um detector de g\u00e1s hidrocarboneto \u00e9 essencial<\/strong><\/h2>\n\n\n\n<p>Os refrigerantes de hidrocarbonetos s\u00e3o inodoros e invis\u00edveis.<br>Portanto, os t\u00e9cnicos n\u00e3o podem confiar no cheiro para encontrar vazamentos.<br>Em vez disso, use um detector de g\u00e1s combust\u00edvel aprovado antes de abrir os pain\u00e9is.<br>Al\u00e9m disso, deixe o detector ligado durante todo o trabalho.<br>Al\u00e9m disso, coloque o detector no ponto de menor probabilidade de acumula\u00e7\u00e3o.<br>Assim, voc\u00ea detectar\u00e1 vazamentos lentos antes que eles atinjam n\u00edveis perigosos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongworkspace-controls-ventilation-and-fire-safety-strong\"><strong>Controles do espa\u00e7o de trabalho, ventila\u00e7\u00e3o e seguran\u00e7a contra inc\u00eandio<\/strong><\/h2>\n\n\n\n<p>Primeiro, realize uma avalia\u00e7\u00e3o formal de risco para cada local.<br>Em seguida, limpe um raio de pelo menos tr\u00eas metros ao redor da unidade.<br>Al\u00e9m disso, remova ou isole quaisquer fontes potenciais de igni\u00e7\u00e3o.<br>Al\u00e9m disso, coloque cartazes vis\u00edveis de advert\u00eancia sobre \u201cRefrigerante Inflam\u00e1vel\u201d.<br>Mantenha um ventilador \u00e0 prova de R290 ou um ventilador remoto pronto para ventila\u00e7\u00e3o de emerg\u00eancia.<br>Por fim, mantenha sempre um extintor de p\u00f3 seco no local.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongtools-recovery-equipment-and-electrical-parts-strong\"><strong>Ferramentas, equipamentos de recupera\u00e7\u00e3o e pe\u00e7as el\u00e9tricas<\/strong><\/h2>\n\n\n\n<p>Utilize somente ferramentas e medidores classificados para hidrocarbonetos.<br>Al\u00e9m disso, utilize bombas de v\u00e1cuo e unidades de recupera\u00e7\u00e3o aprovadas para R290.<br>Al\u00e9m disso, utilize o cilindro de recupera\u00e7\u00e3o correto projetado para hidrocarbonetos.<br>Utilize sempre pe\u00e7as el\u00e9tricas aprovadas pela IEC que n\u00e3o produzam fa\u00edscas.<br>Caso contr\u00e1rio, um rel\u00e9 ou interruptor pode causar igni\u00e7\u00e3o do g\u00e1s vazado.<br>Portanto, substitua as pe\u00e7as suspeitas por itens OEM ou de reposi\u00e7\u00e3o certificados.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongsystem-diagnostics-and-common-failure-causes-strong\"><strong>Diagn\u00f3stico do sistema e causas comuns de falhas<\/strong><\/h2>\n\n\n\n<p>A falha do compressor raramente ocorre por si s\u00f3.<br>Em vez disso, falhas no sistema geralmente causam danos ao compressor.<br>Portanto, realize um diagn\u00f3stico completo do sistema antes de substituir os compressores.<br>Verifique se h\u00e1 fluxo de ar restrito, trocadores de calor bloqueados e carga incorreta.<br>Al\u00e9m disso, inspecione os controles el\u00e9tricos e as linhas de refrigerante para verificar se h\u00e1 danos.<br>Consequentemente, voc\u00ea evitar\u00e1 trocas desnecess\u00e1rias de compressores e visitas repetidas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongservice-workflow-step-by-step-best-practices-strong\"><strong>Fluxo de trabalho de servi\u00e7o: pr\u00e1ticas recomendadas passo a passo<\/strong><\/h2>\n\n\n\n<p>Primeiro, varra o gabinete externo com um detector de g\u00e1s.<br>Depois, examine o interior do gabinete antes de abri-lo.<br>Em seguida, isole a energia e bloqueie as fontes el\u00e9tricas.<br>Depois disso, ventile e mantenha o detector funcionando.<br>Por fim, s\u00f3 energize novamente quando o detector indicar que o ambiente de trabalho est\u00e1 seguro.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongproduct-spotlight-mr-hybrid-built-in-leak-detection-strong\"><strong>Destaque do produto: Mr. Hybrid \u2014 Detec\u00e7\u00e3o de vazamento integrada<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/hetapro.com\/pt\/products\/mr-hybrid-wall-mounted-indoor-r290-hybrid-heat-pump\/\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/mr-hybrid-r290-built-in-refrigerant-leak-detector.webp\" alt=\"mr hybrid r290 built in refrigerant leak detector\" class=\"wp-image-5006\" srcset=\"https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/mr-hybrid-r290-built-in-refrigerant-leak-detector.webp 800w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/mr-hybrid-r290-built-in-refrigerant-leak-detector-300x225.webp 300w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/mr-hybrid-r290-built-in-refrigerant-leak-detector-768x576.webp 768w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/mr-hybrid-r290-built-in-refrigerant-leak-detector-16x12.webp 16w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/mr-hybrid-r290-built-in-refrigerant-leak-detector-600x450.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><figcaption class=\"wp-element-caption\">detector de vazamento de refrigerante integrado mr hybrid r290<\/figcaption><\/figure>\n\n\n\n<p>Hetapro&#039;s <strong><a href=\"https:\/\/hetapro.com\/pt\/products\/mr-hybrid-wall-mounted-indoor-r290-hybrid-heat-pump\/\" data-type=\"link\" data-id=\"https:\/\/hetapro.com\/products\/mr-hybrid-wall-mounted-indoor-r290-hybrid-heat-pump\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sr. H\u00edbrido<\/a><\/strong> \u00e9 uma bomba de calor R290 compacta, montada na parede e para ambientes internos.<br>Notavelmente, o Mr. Hybrid inclui um detector de vazamento de refrigerante integrado como padr\u00e3o.<br>Portanto, os instaladores obt\u00eam monitoramento cont\u00ednuo e integrado de vazamentos desde o primeiro dia.<br>Al\u00e9m disso, o Sr. H\u00edbrido usa uma pequena carga de refrigerante e componentes selados.<br>Dessa forma, simplifica-se o atendimento mantendo alta efici\u00eancia e seguran\u00e7a.<br>Os instaladores apreciar\u00e3o menos etapas de conformidade e comissionamento mais f\u00e1cil.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongproduct-option-heatix-monobloc-optional-leak-detector-strong\"><strong>Op\u00e7\u00e3o de produto: Heatix Monobloc \u2014 Detector de vazamento opcional<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/hetapro.com\/pt\/products\/heatix-r290-monobloc-air-to-water-heat-pump\/\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/heatix-r290-optional-refrigerant-leak-detector.webp\" alt=\"heatix r290 optional refrigerant leak detector\" class=\"wp-image-5007\" srcset=\"https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/heatix-r290-optional-refrigerant-leak-detector.webp 800w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/heatix-r290-optional-refrigerant-leak-detector-300x225.webp 300w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/heatix-r290-optional-refrigerant-leak-detector-768x576.webp 768w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/heatix-r290-optional-refrigerant-leak-detector-16x12.webp 16w, https:\/\/hetapro.com\/wp-content\/uploads\/2025\/10\/heatix-r290-optional-refrigerant-leak-detector-600x450.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><figcaption class=\"wp-element-caption\">detector de vazamento de refrigerante opcional heatix r290<\/figcaption><\/figure>\n\n\n\n<p>Hetapro&#039;s <strong><a href=\"https:\/\/hetapro.com\/pt\/products\/heatix-r290-monobloc-air-to-water-heat-pump\/\" data-type=\"link\" data-id=\"https:\/\/hetapro.com\/products\/heatix-r290-monobloc-air-to-water-heat-pump\/\" target=\"_blank\" rel=\"noreferrer noopener\">Heatix<\/a><\/strong> Bomba de calor ar-\u00e1gua monobloco R290 instalada ao ar livre.<br>Importante: o Heatix pode ser encomendado com um detector de vazamento de refrigerante opcional.<br>Consequentemente, os t\u00e9cnicos podem adaptar o monitoramento \u00e0s demandas do local.<br>Al\u00e9m disso, a coloca\u00e7\u00e3o ao ar livre reduz o risco de ac\u00famulo em ambientes internos.<br>No entanto, a detec\u00e7\u00e3o opcional ainda melhora a seguran\u00e7a e a detec\u00e7\u00e3o precoce de falhas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongregulatory-and-practical-benefits-strong\"><strong>Benef\u00edcios regulat\u00f3rios e pr\u00e1ticos<\/strong><\/h2>\n\n\n\n<p>O R290 tem PAG ultrabaixo e nenhum potencial de destrui\u00e7\u00e3o da camada de oz\u00f4nio.<br>Portanto, ele apoia metas de sustentabilidade e reduz o impacto de carbono.<br>Al\u00e9m disso, os projetos modernos de baixo custo reduzem a complexidade da instala\u00e7\u00e3o.<br>No entanto, a conformidade exige treinamento, pe\u00e7as corretas e detec\u00e7\u00e3o de vazamentos.<br>Portanto, investir em detectores e ferramentas certificadas protege pessoas e propriedades.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"strongconclusion-practical-steps-for-safe-r290-service-strong\"><strong>Conclus\u00e3o: Etapas pr\u00e1ticas para um servi\u00e7o seguro de R290<\/strong><\/h2>\n\n\n\n<p>Sempre considere um refrigerante inflam\u00e1vel at\u00e9 que se prove o contr\u00e1rio.<br>Em seguida, use um detector de g\u00e1s aprovado, ventile e isole a energia.<br>Al\u00e9m disso, utilize ferramentas com classifica\u00e7\u00e3o R290 e pe\u00e7as el\u00e9tricas aprovadas pela IEC.<br>Por fim, escolha equipamentos com detec\u00e7\u00e3o integrada sempre que poss\u00edvel.<br>Por exemplo, o Mr. Hybrid inclui um detector de vazamento integrado como padr\u00e3o.<br>Enquanto isso, o monobloco Heatix oferece detec\u00e7\u00e3o de vazamentos como op\u00e7\u00e3o.<br>Assim, com treinamento e o equipamento certo, os sistemas R290 s\u00e3o seguros e eficientes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions-faq\">Perguntas Frequentes (FAQ)<\/h2>\n\n\n\n<p><strong>Q1 \u2014 O R290 \u00e9 seguro para bombas de calor internas?<\/strong><br>Sim. Quando instalado conforme as orienta\u00e7\u00f5es do fabricante, com baixa carga de refrigerante e detec\u00e7\u00e3o de vazamentos, o R290 \u00e9 seguro.<\/p>\n\n\n\n<p><strong>Q2 \u2014 Preciso de um certificado de g\u00e1s fluorado para instalar ou fazer a manuten\u00e7\u00e3o de unidades R290?<\/strong><br>Geralmente n\u00e3o para sistemas de propano, mas as regras locais variam. Sempre confirme as regulamenta\u00e7\u00f5es nacionais antes de trabalhar.<\/p>\n\n\n\n<p><strong>Q3 \u2014 Por que um detector de vazamento de refrigerante \u00e9 essencial?<\/strong><br>O R290 \u00e9 inodoro e mais pesado que o ar. Detectores detectam vazamentos precocemente e previnem concentra\u00e7\u00f5es perigosas.<\/p>\n\n\n\n<p><strong>Q4 \u2014 Onde devo colocar o detector de g\u00e1s durante a manuten\u00e7\u00e3o?<\/strong><br>Coloque-o na parte baixa do arm\u00e1rio e no ch\u00e3o, em frente ao local de trabalho. Mantenha-o ligado durante todo o trabalho.<\/p>\n\n\n\n<p><strong>Q5 \u2014 Com que frequ\u00eancia devo testar ou calibrar detectores?<\/strong><br>Verifique os detectores antes de cada trabalho. Calibre-os ou fa\u00e7a a manuten\u00e7\u00e3o conforme o cronograma do fabricante.<\/p>\n\n\n\n<p><strong>Q6 \u2014 Posso usar minha bomba de recupera\u00e7\u00e3o e cilindros existentes?<\/strong><br>Somente se forem certificados para hidrocarbonetos. Caso contr\u00e1rio, utilize m\u00e1quinas de recupera\u00e7\u00e3o com classifica\u00e7\u00e3o R290 e cilindros aprovados.<\/p>\n\n\n\n<p><strong>Q7 \u2014 Quais equipamentos e ferramentas de prote\u00e7\u00e3o individual s\u00e3o necess\u00e1rios?<\/strong><br>Use luvas antiest\u00e1ticas, prote\u00e7\u00e3o para os olhos, ferramentas antifa\u00edscas aprovadas pela IEC e medidores \u00e0 prova de fa\u00edscas ao trabalhar com R290.<\/p>\n\n\n\n<p><strong>Q8 \u2014 E se eu encontrar um vazamento durante o servi\u00e7o?<\/strong><br>Interrompa o trabalho, ventile a \u00e1rea, evacue o pessoal n\u00e3o essencial, coloque avisos e repare com pe\u00e7as aprovadas. Verifique a seguran\u00e7a com o detector antes de reenergiz\u00e1-lo.<\/p>\n\n\n\n<p><strong>Q9 \u2014 O Hetapro oferece detec\u00e7\u00e3o de vazamento integrada?<\/strong><br>Sim. O <strong>Sr. H\u00edbrido<\/strong> A bomba de calor R290 de parede interna inclui um detector de vazamento de refrigerante integrado como padr\u00e3o. A bomba de calor externa <strong>Heatix<\/strong> monobloco oferece detec\u00e7\u00e3o de vazamentos como acess\u00f3rio opcional.<\/p>","protected":false},"excerpt":{"rendered":"<p>Guia essencial de seguran\u00e7a do R290 para t\u00e9cnicos e instaladores de HVAC. Aprenda sobre detec\u00e7\u00e3o de vazamentos, ferramentas de seguran\u00e7a, pr\u00e1ticas de ventila\u00e7\u00e3o e recursos da bomba de calor Mr. Hybrid R290.<\/p>","protected":false},"author":1,"featured_media":5009,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"R290 Refrigerant Safety & Leak Detection Guide for Technicians","_seopress_titles_desc":"Essential R290 safety guide for HVAC technicians and installers. Learn leak detection, safe tools, ventilation practices, and Mr. Hybrid R290 heat pump features.","_seopress_robots_index":"","footnotes":""},"categories":[67],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/posts\/5003"}],"collection":[{"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/comments?post=5003"}],"version-history":[{"count":2,"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/posts\/5003\/revisions"}],"predecessor-version":[{"id":5016,"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/posts\/5003\/revisions\/5016"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/media\/5009"}],"wp:attachment":[{"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/media?parent=5003"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/categories?post=5003"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hetapro.com\/pt\/wp-json\/wp\/v2\/tags?post=5003"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}