Поиск
Industrial Heat Pump Applications & Industry Solutions | HETAPRO
Aerial view of an industrial plant with heat pump units and rooftop pipework
Applications & Industry Solutions

Find your industry.
Retire your boiler.

Dye baths, CIP loops, wash water, drying air and low-pressure steam — the heat your plant burns fuel for every day, delivered by a heat pump instead. Start from your industry or from your process temperature — both roads lead to the same sized scheme.

30–150 °CCovered output range
6 seriesHot water · Steam · Hot air
3 deep-divesIndustry solution guides
380–415 V / 50 HzExport-standard electricals

Industry solution guides

Each guide is built around real process temperatures and real fuel prices — with an interactive selector, a payback calculator and the honest boundaries of where a heat pump stops making sense. All three run large, continuously scheduled heat demand between 60 °C and 150 °C — the window where a heat pump beats a boiler on running cost, and where the process is stable enough to size against real load rather than nameplate.

Guide live Aerial view of a textile processing plant
TextilesDyeing · Finishing · Washing · Drying
60–135 °C process water 110–150 °C steam 30–85 °C stenter air

Dye baths and scouring at 80–135 °C, rinsing and wash lanes at 60–90 °C, thermosol and finishing steam, and hot-air drying from a single product family. Includes a dedicated regional guide for Bangladesh dyeing houses with local fuel prices and a break-even COP analysis against HSD and LNG.

Open the textile solution guide →
Guide live Dairy filling line with glass milk bottles and stainless steel pipework
Еда и напиткиCIP · Pasteurisation · Evaporation
Six temperature segments Interactive selector TCO calculator

CIP cleaning at 80 °C, pasteurisation at 72–85 °C, blanching at 90–100 °C, evaporation at 56 °C — mapped onto six continuous temperature segments up to 150 °C UHT steam, with the pressure boundary stated honestly: 121 °C retort sterilisation stays on the boiler because it needs pressurised saturated steam, not because of temperature.

Open the F&B solution guide →
Guide live Glowing semiconductor die on a circuit board with copper traces, representing battery and wafer manufacturing
New Energy & ElectronicsBattery · Dry rooms · Wafers
85–130 °C electrode drying −40 °C dew-point dry rooms 60–90 °C hot UPW

Cathode coating lines run 85–130 °C, anode lines 75–110 °C, dry-room desiccant wheels need 120–140 °C regeneration and wafer wet benches hold 65–85 °C baths plus 60–90 °C hot ultrapure water. The guide pairs both industries with a series selector and a ten-year TCO calculator, and states the ceilings plainly: diffusion and CVD at 800–1,200 °C are not in range.

Open the New Energy & Electronics guide →

More applications we serve

Dedicated guides for these industries are in production. In the meantime, our engineers size schemes for all of them today — send your load profile and we will return an indicative COP and payback range for your case.

Chemical & process

Page in prep

Reactor and storage-tank preheat, distillation reboiler preheat, solvent recovery and spray-drying upstream heat — delivered as 95–135 °C water or 110–150 °C low-pressure steam from HT-W2S / HT-A2S.

Typical dutiesJacket water 90 °C · reboiler preheat 110–130 °C · drying air
Ask for a sizing note →

Pulp & paper

Page in prep

Boiler feedwater preheat, bleaching-stage hot water and dryer-section make-up air. Feedwater preheat alone is often the fastest payback in the mill: it displaces the cheapest-to-replace steam duty and cuts blowdown losses.

Typical dutiesFeedwater preheat 80–95 °C · whitewater 60–80 °C · hot air
Ask for a sizing note →

Surface treatment & plating

Page in prep

Degreasing tanks at 60–80 °C, rinse-water heating and electroplating bath temperature stability. Tanks run on circulating hot water — the exact form a heat pump delivers — and rectifier waste heat can be lifted back into the loop with a water-source MT-W2W.

Typical dutiesDegrease 65–80 °C · nickel/chrome baths 50–65 °C · rinses
Ask for a sizing note →

Wood & biomass drying

Page in prep

Kiln and chamber drying at 40–80 °C with controlled humidity. The MT-A2A inverter dryer holds setpoint through the full schedule without gas-fired make-up air, and condensate from the drying air can be recovered as warm water for the next charge.

Typical dutiesKiln air 40–80 °C · chamber heat · dehumidification
Ask for a sizing note →

Laundry & commercial

Page in prep

Wash water at 60–85 °C, tunnel-washer final rinse at 82 °C and tumble-dryer make-up air for hospital linen, hotel groups and industrial laundries. Demand is flat and scheduled — the ideal load shape for heat pumps and thermal storage.

Typical dutiesWash 60–85 °C · rinse 82 °C · dryer air 60–85 °C
Ask for a sizing note →

Your industry

On request

If your process moves liquid, air or low-pressure steam anywhere between 30 °C and 150 °C, it is a candidate. The sizing logic starts from three numbers: process temperature, annual heat demand, and what you currently pay per unit of heat.

What to send usTemperature levels · load profile · current fuel cost
Start the conversation →

Choose by output

If you already know the form of heat your process needs, go straight to the series that produces it.

HETAPRO product series mapped by output. Click any model to open its product page.
OutputSeriesSource → sinkMax. output temp.КомпрессорTypical capacity
Hot water — standard temp. MT-A2W Окружающий воздух95 °CПрокрутить350 kW
Hot water — water source MT-W2W Water / waste heat95 °CScrew + VFD1,500 kW
Hot water — high temp. HT-A2W Окружающий воздух135 °CPiston220 kW
Steam — water source HT-W2S Water / waste heat150 °CScrewSteam plant
Steam — air source HT-A2S Окружающий воздух150 °CPistonSteam plant
Hot air — drying MT-A2A Окружающий воздух30–85 °CInverter scrollDirect air

Часто задаваемые вопросы

Which industries are the strongest fit for high-temperature heat pumps?
Industries with large, scheduled hot-water or steam demand between 60 °C and 150 °C see the fastest payback. Our three deepest guides cover textiles, food & beverage и new energy & electronics. Chemical process heat, pulp and paper, surface treatment, timber drying and commercial laundries are also strong candidates — ask us for a sizing note.
We already run steam boilers. Can heat pumps work alongside them?
Yes — and that hybrid architecture is what we recommend. The heat pump carries the base load (washing, rinsing, CIP, feedwater preheat) while the existing boiler covers peaks. The genuinely high-pressure duty — for example 121 °C retort sterilisation, which needs pressurised saturated steam — stays on the boiler side. This is a thermodynamic boundary, not a product limitation.
What temperature range do HETAPRO heat pumps cover?
From 30 °C to 150 °C across six series: MT-A2W и MT-W2W deliver up to 95 °C hot water, HT-A2W up to 135 °C hot water, HT-W2S и HT-A2S deliver 110–150 °C steam, and MT-A2A delivers 30–85 °C hot air for drying.
There is no dedicated page for my industry yet. Can you still size a system?
Yes. Send your process temperature levels, load profile and current fuel or electricity cost through the contact page. Our engineers will return a sizing note with an indicative COP and payback range for your specific case — usually within a week.

Not sure where your process fits?

Send us your process temperature levels, annual heat demand and current energy bill. You will get an indicative COP, a payback range and a recommended series — before any commitment.

Contact our engineers Browse by output

ГЕТАПРО — Industrial high-temperature heat pumps: hot water to 95–135 °C, steam to 150 °C, drying air 30–85 °C.

Textile solutions · Food & beverage solutions · Контакт

© 2026 HETAPRO. All specifications subject to change; indicative figures on this page are engineering guidance, not contractual performance data.

Отправьте нам запрос

Ваша информация будет храниться строго конфиденциально.

Отправьте нам запрос

Ваша информация будет храниться строго конфиденциально.