GMCC R32 full DC inverter two-stage compressor ensures high temperature water output at low temperature.
Electric
8/10/12/14/16KW
R32 DC Twin rotary
≤50
65°C
Erp A+++,CE,EMC,
Keymark,MCS,Rohs
Optional 4-inch touch screen controller
DC fan + DC water pump, intelligent and low consumption
Sheet pitch 1.4, hole pitch 21, row pitch 18.19, ensuring capacity and energy efficiency
Minimum 50 dBA
Multi-function controller, dual-zone heat source management
SG ready automatically matches smart grid control
Power monitoring system, monitor power consumption at any time
Multi-level intelligent defrosting system ensures uninterrupted operation of the machine
The heat pump adapts to different electrical signals. The energy consumption of the system can be automatically adjusted based on peak and low power, minimizing heating costs. With this feature, the pump will automatically start to utilize cheaper energy prices or store excess electricity from the photovoltaic system.
There are a total of 32 climate curves(16 cooling curves+16 heating curves) for user to choose from,and there are also 2 curves(1 cooling curve+1 heating curve) for users to customize.
After selecting a certain climate curve,the target water temperature of the unit will be automatically set based on the outdoor ambient temperature(using different set water temperatures at different ambient temperatures will be more comfortable and energy-saving).
Unit Dimension
1128*500*915mm
Power
8/10/12/14/16KW
We provide HTA training system – Hetapro training academics to help you achieve product use, market analysis, competitive research, etc.
Tailor-made for you, our solution guarantees optimal results with custom Appearance, performance, systems, etc.
HTA Training System – Hetapro Training Academic, helping you with product selection, installation and commissioning and maintenance training.
3 years, part of components free.
Outdoor unit model name
|
HEAW08MRN3-A
|
HEAW10MRN3-A
|
||
Power supply
|
V/Ph/Hz
|
220V/1ph
|
||
Heating A7W35
|
Capacity
|
kW
|
8.00
|
10.00
|
Rated input
|
kW
|
1.66
|
2.08
|
|
COP
|
4.81
|
4.81
|
||
Heating A7W45
|
Capacity
|
kW
|
8.00
|
10.00
|
Rated input
|
kW
|
2.13
|
2.67
|
|
COP
|
3.75
|
3.75
|
||
Heating A7W55
|
Capacity
|
kW
|
7.50
|
9.50
|
Rated input
|
kW
|
2.46
|
3.11
|
|
COP
|
3.05
|
3.05
|
||
Cooling A35W18
|
Capacity
|
kW
|
7.90
|
9.90
|
Rated input
|
kW
|
2.18
|
2.18
|
|
EER
|
4.55
|
4.55
|
||
Cooling A35W7
|
Capacity
|
kW
|
6.20
|
8.20
|
Rated input
|
kW
|
2.52
|
2.52
|
|
EER
|
2.46
|
3.25
|
||
ERP
|
Water outlet at 35℃
|
A+++
|
A+++
|
|
Water outlet at 55℃
|
A++
|
A++
|
||
SCOP
|
Water outlet at 35℃
|
4.98
|
4.98
|
|
Water outlet at 55℃
|
3.35
|
3.35
|
||
Sound power Level3
|
Heating A7W35
|
dB
|
60
|
60
|
Compressor
|
Type
|
R32 DC Twin rotary
|
R32 DC Twin rotary
|
|
Outdoor fan
|
Motor type
|
DC motor
|
DC motor
|
|
Number of fans
|
1
|
1
|
||
Air side heat exchanger
|
Φ7 Fin coil
|
Φ7 Fin coil
|
||
Water side heat exchanger
|
Plate type
|
Plate type
|
||
Throttle
|
Type
|
Electronic expansion valve
|
Electronic expansion valve
|
|
Refrigerant
|
R32/1.2kg
|
R32/1.2kg
|
||
Water pump
|
Type
|
DC invertor
|
DC invertor
|
|
Max. pump head
|
m
|
9
|
9
|
|
Expansion vessel
|
Volume
|
L
|
5
|
5
|
Max. working pressure
|
bar
|
8
|
8
|
|
Safety valve
|
Pressure
|
MPa
|
0.36
|
0.36
|
Water side connection
|
R5/4″
|
R5/4″
|
||
Unit dimension (W×H×D)
|
mm
|
1137×912×500
|
1137×912×500
|
|
Packing dimension (W×H×D)
|
mm
|
1215×1055×550
|
1215×1055×550
|
|
Net/Gross weight
|
kg
|
108/142
|
108/142
|
|
Outdoor air temperature range
|
Cooling
|
℃
|
-5 ~43
|
-5 ~43
|
Heating
|
℃
|
-25 ~ 35
|
-25 ~ 35
|
|
DHW
|
℃
|
-25 ~43
|
-25 ~43
|
|
Water outlet temperature range
|
Cooling
|
℃
|
5 ~ 30
|
5 ~ 30
|
Heating
|
℃
|
12 ~ 65
|
12 ~ 65
|
|
DHW ( tank )
|
℃
|
10 ~ 60
|
10 ~ 60
|
|
Notes:
1. Relevant EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811/2013; (EU) No 813/2013; OJ 2014/C 207/02. 2. Seasonal space heating energy efficiency class tests in average climate conditions. 3. Sound power test condition :EN12102- 1 |
||||
DHW: Domestic hot water.
|
Outdoor unit model name
|
HEAW12MRN3-A
|
HEAW14MRN3-A
|
HEAW16MRN3-A
|
||
Power supply
|
V/Ph/Hz
|
220V/1ph 380V/3ph
|
|||
Heating A7W35
|
Capacity
|
kW
|
12.00
|
14.00
|
16.00
|
Rated input
|
kW
|
2.55
|
3.11
|
3.56
|
|
COP
|
4.70
|
4.50
|
4.50
|
||
Heating A7W45
|
Capacity
|
kW
|
12.30
|
14.00
|
16.00
|
Rated input
|
kW
|
3.32
|
4.00
|
4.57
|
|
COP
|
3.7
|
3.5
|
3.5
|
||
Heating A7W55
|
Capacity
|
kW
|
11.50
|
14.00
|
16.00
|
Rated input
|
kW
|
3.77
|
5.09
|
5.82
|
|
COP
|
3.05
|
2.75
|
2.75
|
||
Cooling A35W18
|
Capacity
|
kW
|
12.00
|
12.90
|
14.90
|
Rated input
|
kW
|
3.04
|
4.38
|
4.38
|
|
EER
|
3.95
|
3.4
|
3.4
|
||
Cooling A35W7
|
Capacity
|
kW
|
9.84
|
12.00
|
14.00
|
Rated input
|
kW
|
3.02
|
5.19
|
5.19
|
|
EER
|
3.26
|
2.31
|
2.70
|
||
ERP
|
Water outlet at 35℃
|
A+++
|
A+++
|
A+++
|
|
Water outlet at 55℃
|
A++
|
A++
|
A++
|
||
SCOP
|
Water outlet at 35℃
|
5.33
|
4.83
|
4.83
|
|
Water outlet at 55℃
|
3.70
|
3.36
|
3.36
|
||
Sound power Level3
|
Heating A7W35
|
dB
|
65
|
68
|
68
|
Compressor
|
Type
|
R32 DC Twin rotary
|
R32 DC Twin rotary
|
R32 DC Twin rotary
|
|
Outdoor fan
|
Motor type
|
DC motor
|
DC motor
|
DC motor
|
|
Number of fans
|
1
|
1
|
1
|
||
Air side heat exchanger
|
Φ7 Fin coil
|
Φ7 Fin coil
|
Φ7 Fin coil
|
||
Water side heat exchanger
|
Plate type
|
Plate type
|
Plate type
|
||
Throttle
|
Type
|
Electronic expansion valve
|
Electronic expansion valve
|
Electronic expansion valve
|
|
Refrigerant
|
R32/1.5kg
|
R32/1.8kg
|
R32/1.8kg
|
||
Water pump
|
Type
|
DC invertor
|
DC invertor
|
DC invertor
|
|
Max. pump head
|
m
|
9
|
9
|
9
|
|
Expansion vessel
|
Volume
|
L
|
5
|
5
|
5
|
Max. working pressure
|
bar
|
8
|
8
|
8
|
|
Safety valve
|
Pressure
|
MPa
|
0.36
|
0.36
|
0.36
|
Water side connection
|
R5/4″
|
R5/4″
|
R5/4″
|
||
Unit dimension (W×H×D)
|
mm
|
1137×912×500
|
1137×912×500
|
1137×912×500
|
|
Packing dimension (W×H×D)
|
mm
|
1215×1055×550
|
1215×1055×550
|
1215×1055×550
|
|
Net/Gross weight
|
kg
|
114/148
|
120/154
|
120/154
|
|
Outdoor air temperature range
|
Cooling
|
℃
|
-5 ~43
|
-5 ~43
|
-5 ~43
|
Heating
|
℃
|
-25 ~ 35
|
-25 ~ 35
|
-25 ~ 35
|
|
DHW
|
℃
|
-25 ~43
|
-25 ~43
|
-25 ~43
|
|
Water outlet temperature range
|
Cooling
|
℃
|
5 ~ 30
|
5 ~ 30
|
5 ~ 30
|
Heating
|
℃
|
12 ~ 65
|
12 ~ 65
|
12 ~ 65
|
|
DHW ( tank )
|
℃
|
10 ~ 60
|
10 ~ 60
|
10 ~ 60
|
|
Notes:
1. Relevant EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811/2013; (EU) No 813/2013; OJ 2014/C 207/02. 2. Seasonal space heating energy efficiency class tests in average climate conditions. 3. Sound power test condition :EN12102- 1 |
|||||
DHW: Domestic hot water.
|
item
|
value
|
After-sales Service Provided
|
Free spare parts
|
Warranty
|
1 Year
|
Application
|
Household
|
Power Source
|
Electric
|
App-Controlled
|
Yes
|
Private Mold
|
Yes
|
Type
|
Air Source Heat Pump
|
Installation
|
Freestanding
|
Storage / Tankless
|
Other
|
Housing Material
|
Plastic
|
Use
|
Bathroom/floor heating/DHW/fan coil
|
Place of Origin
|
China
|
Guangdong
|
|
Brand Name
|
HETA
|
Model Number
|
HEAW12MRN3-A
|
stylish
|
mono
|
easy installation
|
good quality
|
functional
|
wifi and app
|
Your information will be kept strictly confidential.