Your Trusted Partner in Heat Pump Solutions
Use the power of nature Inspire hope for a greener future
Process heat from ambient air — 95°C hot water, 85°C hot air, no waste heat needed.
For food, agricultural and textile plants that cannot justify a steam-system investment. Six industrial models, 220–1,500 kW, built in Foshan since 2004.
Product categoriesExplore Our Product Range
Two main lines for self-funded plants, plus a steam line supplied for EPC and subsidised projects.
Industrial Heat Pump Solution
Empower industrial decarbonization with HETAPRO high-temperature heat pumps—delivering up to 150°C steam and ultra-efficient process heating to drastically cut boiler operational costs and carbon emissions.
Residential Heat Pump Solution
Heating, cooling and domestic hot water all-in-one solution
ErP A+++(35℃/55℃)
R290 natural refrigerant
Operation range: -25 to 45℃
Max temp outlet: 80℃
Commercial Heat Pump Solution
R410a and R32 ErP combinable modular chiller, with optional low ambient kit and max. 16 units in group control, can satisfy all kind of commercial applications.
Capacity range: 35 to 250kW single model
Hydro Split Water System Solution
The Hydraulic System is an all-in-one water system that includes a water tank, buffer tank, and expansion tank. This eliminates the need for separate water system installations, making it a convenient option for brand owners and distributors.
Where These Two Lines Fit
Hot water for process plants; hot air for drying plants. Neither needs a waste-heat stream.
† Steam and 135°C hot water are supplied for EPC / policy projects only and require a 55–85°C waste-heat stream.
Three Reasons Plants Choose These Lines
Lower Carbon Footprint
All six models are electric-driven: no on-site combustion, no NOx, no flue gas, no boiler house to permit. The 95°C hot water and 85°C hot air lines run on ambient air, so no waste-heat stream is needed.
High Energy Efficiency
One published, measured COP: 2.69–2.70 for the 1,500 kW water-source unit at source 60/52°C → supply 87/95°C (MT-W2W). We quote performance at your source and supply temperatures — ask for the datasheet at your duty. Compressors are inverter-driven (Danfoss / HANBELL).
Intelligent Control
RS485 / Modbus RTU on four models — master or slave, so your SCADA or BMS can read and drive the unit. Hold temperature, and humidity in drying, to protect product grade. Controller language and supply voltage are configurable per project; published supply is 380 V / 3N / 50 Hz — confirm before ordering for a 60 Hz grid.
Industrial High-Temp Heat Pump Solutions
Every figure below carries its operating condition. Where we have no value, we say so.

95°C Hot Water — Washing, CIP, Pasteurizing, Dyeing
The line most plants start with. It replaces a hot-water boiler or electric heater without needing waste heat. Atmospheric, no pressure vessel.
- OUTPUT 95°C hot water
- SOURCE ambient ≥10°C / water 60/52°C
- CAPACITY 350 kW · up to 16 parallel
- WATER SOURCE 1,500 kW single unit

85°C Hot Air — Product & Textile Drying
Clean, controllable hot air from 30 to 85°C for food, crops, herbs, timber and fabric — no combustion, no flue, no fire risk, and humidity control a gas dryer cannot give.
- OUTPUT 30–85°C hot air (60°C rated)
- INLET air 0–80°C
- CAPACITY 300 kW (MT-A2A)
- SUPPLY 380V / 3N / 50Hz

150°C Steam & 135°C Hot Water †
Supplied where a 55–85°C waste-heat stream already exists and the economics are backed by a subsidy, carbon programme or EPC project. At 150°C, saturated steam is about 3.76 bar(g) — a steam-table value, not a machine rating.
- STEAM 110–150°C · 220 / 500 kW
- HOT WATER 100–135°C · 220 kW
- SOURCE 55–85°C waste heat required
- ONLY PUBLISHED COP 2.69–2.70 ††
ISO Quality Control & OEM/ODM Capability
Traceable documents and a factory you can audit — not adjectives.
Manufacturing Strength
Built in Foshan, Guangdong, since 2004. Configuration, supply voltage and refrigerant arrangement are specified per order; capacity and lead time are confirmed per configuration at enquiry.
- ISO 9001 — Quality Management System
- ISO 14001 — Environmental Management System
- ISO 45001 — Occupational Health & Safety
- Model datasheets and written test conditions on request
OEM & ODM Heat Pump Solutions
You can change the cabinet, badge, controller language, supply voltage and refrigerant configuration. The compressor and core heat exchanger stay ours — they are why the performance holds.
- Experienced R&D and manufacturing teams
- Professional sales and channel management
- Territory registered by country and industry
- Customs-ready documentation and priced spare-parts list
Published supply is 380–415V / 50 Hz three-phase. Confirm availability before ordering for a 60 Hz grid.
About Hetapro
Heating professional, since 2004.
HETAPRO designs and manufactures heat pumps for industrial process heat. The name combines “heating” and “professional” — design, product and service as one deliverable.
Heating professional, since 2004.
Our focus now is the heat most factories actually need: 95°C water and 85°C hot air, produced from ambient air without a waste-heat stream or a fuel boiler. Steam systems are supplied where a project, not a plant, pays for them.
Read More About UsLatest NewsInsights for HTHP Buyers
Financing, tariffs and the rules that now set industrial heat-pump payback.
Send us an inquiry
Your information will be kept strictly confidential.